Installation
4-9
7. Verify front panel button operation. To do this, select the following options in
the order in which they are listed, using the buttons on the front panel:
8. Verify remote operation from the remote terminal keyboard. To do this, at the
system prompt, type
EM ?
and press
E
NTER
.
A response of
EM 1
or
EM 0
should appear on the display followed by the
system prompt >.
9. If the optional BERT option is installed, perform a BERT loopback test to
verify basic modem operation. For additional information on the BERT IF
Loopback test, refer to the chapter on troubleshooting and the BERT
appendix.
To perform the loopback test, the IF loopback cable provided must be attached
between the TxIF connector and the RxIF connector on the modem card.
Additional Testing
Additional testing may be performed if test equipment is available and extensive
specification compliance is necessary. Specification compliance tests for RF
power, dynamic range, acquisition range, acquisition time, symbol rate range,
aggregate power, and many other parameters can be performed.
For information on tests specific to option cards installed in a CM601, refer to the
specific user guide that accompanies each option card.
Completion of the Bench-Top Test
The CM601 system is now tested and verified. This concludes the bench-top
functional verification test sequence for the CM601. If no further testing is
required, power off the unit and proceed to the next section.
Table 4-3
Front Panel Button Operation Verification
Button or Option
LCD Message Display
Remarks
Any LCD button
Config Monitor Faults
These buttons are located directly below the
LCD and have t-shaped icons above them
Config 4:Systm 4:M&C
More
—
More
5:Modem
More
—
5:Modem
TxDataRate
TxDataRate is the first of the list of modulator
commands that appears
Previous button
5:Modem
More
—
Previous button
Config Monitor Faults
—
Summary of Contents for CM601
Page 4: ...iv Notice COMSTREAM A Spar Company...
Page 12: ...xii Contents COMSTREAM A Spar Company...
Page 86: ...6 14 Front Panel Operation COMSTREAM A Spar Company...
Page 96: ...7 10 Configuration Examples COMSTREAM A Spar Company...
Page 118: ...8 22 Fault Handling Troubleshooting and Maintenance COMSTREAM A Spar Company...
Page 124: ...A 6 Technical Specifications COMSTREAM A Spar Company...
Page 160: ...xii Safety Precautions 01 0799 401D 08 02...
Page 164: ...4 Functional Description 01 0799 401D 08 02...
Page 170: ...10 Card Removal Procedure 01 0799 401D 08 02...
Page 204: ...44 Fault and Status Queries 01 0799 401D 08 02...
Page 208: ...48 Loopback Tests 01 0799 401D 08 02...
Page 216: ...56 Appendix A Technical Specifications and Pinouts 01 0799 401D 08 02...
Page 220: ...60 01 0799 401D 08 02...
Page 222: ...D 08 02 01 0799 401 Index 62...