8-4
Fault Handling, Troubleshooting, and Maintenance
The fault log, which is a historical record of CM601 fault conditions, can be
queried using the following commands:
Fault Log query (FL ?) — this remote command returns a decimal number
representing the bit-mapped fault log register. The decimal number must be
converted to binary, the binary 1s must be located, and, finally, the bit
locations of the binary 1s must be matched with the corresponding faults.
View Faults query (VF ?) — this remote command displays a complete card
listing that includes the name of the card, slot location, and descriptions of all
faults that have occurred since the faults were last cleared.
View Faults with Time Stamp query (VFT ?) — this remote command
displays a list of only the first 10 faults that occurred since the fault log
register was cleared. The list includes fault descriptions with date and time
stamps. The information is saved in volatile memory for subsequent viewing.
This feature is very helpful when tracking infrequent system problems,
especially those that occur at unmanned sites.
Fault Log — this front panel command displays the fault log. If there are no
fault conditions,
Modem FaultLog is Clear
is displayed. If there are
faults, they are displayed in a scrollable list.
Standard CM601 Faults
CM601 faults are listed in Table 8-1 by fault log register bit. Included for each
fault is the:
Fault log register bit
Weight
Displayed fault message
Type of fault, either:
Hardware (H) – caused by a circuitry failure in the CM601; usually
requires diagnosis and replacement of a faulty card
Operational (O) – indicates real or potential problem in the
communications path; requires search for an abnormal operating
condition and action as appropriate
Description of the fault
Possible causes of the fault
Summary of Contents for CM601
Page 4: ...iv Notice COMSTREAM A Spar Company...
Page 12: ...xii Contents COMSTREAM A Spar Company...
Page 86: ...6 14 Front Panel Operation COMSTREAM A Spar Company...
Page 96: ...7 10 Configuration Examples COMSTREAM A Spar Company...
Page 118: ...8 22 Fault Handling Troubleshooting and Maintenance COMSTREAM A Spar Company...
Page 124: ...A 6 Technical Specifications COMSTREAM A Spar Company...
Page 160: ...xii Safety Precautions 01 0799 401D 08 02...
Page 164: ...4 Functional Description 01 0799 401D 08 02...
Page 170: ...10 Card Removal Procedure 01 0799 401D 08 02...
Page 204: ...44 Fault and Status Queries 01 0799 401D 08 02...
Page 208: ...48 Loopback Tests 01 0799 401D 08 02...
Page 216: ...56 Appendix A Technical Specifications and Pinouts 01 0799 401D 08 02...
Page 220: ...60 01 0799 401D 08 02...
Page 222: ...D 08 02 01 0799 401 Index 62...