Table 5-11
ServerNet I Panic Messages
continued
Messages
Description
User Action
ship_PCI_initialize: Found n
ServerNet I PCI adapters—
currently only one ServerNet I
PCI adapter supported
Indicates that during the
discovery and initialization of the
SPA, more than one SPA was
found
Ensure that only one SPA 1.5
revision E is installed in the local
node. With one SPA in the node,
run the resource manager
(resmgr) command and verify
that the SPA (displayed as
“ship” in the report) displays
only once. If it displays twice,
use resmgr to remove the entry
having the most empty fields,
use idconfupdate to update the
system configuration files, and
then reboot the node.
ship_PCI_initialize: No
ServerNet I PCI adapter found
Indicates that during the
discovery and initialization of the
SPA, no SPA was found
Ensure that an SPA 1.5
revision E is installed in local
node. Run the resource manager
(resmgr) command and verify
that the SPA (displayed as
“ship” in the report) is listed.
ship_init: Unknown revision of
the SAIL ASIC detected
CIN=0xnnnnnnnn
The SAIL ASIC detected is not
revision A or revision B
Replace the SPA with a 1.5
revision E SPA in the local node.
ship_init: Unknown revision of
the ServerNet I PCI adapter
found Rev ID=0xn
Indicates that during the
discovery and initialization of the
SPA, an unknown revision of the
SPA was detected. The SPA
driver recognizes a number of
versions of the SPA. ProLiant
Clusters for SCO UnixWare 7
support only the 1.5 Rev C and
1.5 Rev E SPAs.
Replace the SPA with a 1.5
revision E SPA in the local node.
ship_init: Unsupported
MITE-based ServerNet I PCI
adapter detected
Unsupported MITE-based
ServerNet I PCI adapter found
These messages indicate that
during the discovery and
initialization of the SPA, a
MITE-based SPA was found.
MITE-based SPAs are not
supported by ProLiant Clusters
for SCO UnixWare 7.
Ensure that the SPA is version
1.5 revision E. If so, the SPA
configuration files may be
corrupt. Call product support
personnel.
continued