5-4
Compaq ProLiant Clusters for SCO UnixWare 7 U/300 Quick Install Guide for the Compaq ProLiant DL380
Compaq Confidential – Need to Know Required
Writer:
Rachel Williams
Project:
Compaq ProLiant Clusters for SCO UnixWare 7 U/300 Quick Install Guide for the Compaq ProLiant DL380
Comments:
Part Number:
221544-001
File Name:
f-ch5 Troubleshooting.doc
Last Saved On:
12/27/00 11:01 AM
Quick Install Error Messages
This section addresses errors relating to Quick Install installation.
Table 5-2
Quick Install Error Messages
Error Message
Possible Cause
Action
No internal disk drive
Add a 9.1-GB or larger disk drive and
configure the system with the
SmartStart. See Chapter 2, “Setting Up
Cluster Hardware” and Chapter 3,
“Installing Cluster Software” of this
guide.
Server not configured with
SmartStart
Follow the instructions for configuring
the server with the SmartStart. See
Chapter 3 of this guide.
No Fibre Channel HBA
Install the Fibre Channel HBA adapter,
follow the cabling instructions, and
configure the server with the SmartStart.
See Chapter 2 and Chapter 3 of this
guide.
Failed Fibre Channel HBA,
GBIC-SW, cable, or
StorageWorks RAID
Array 4100 storage
subsystem
Replace failed component.
No disks drives (or only 1) in
RA4100
Add disk drives as described in
Chapter 2 of this guide.
No disks found
RA4100 disks drives in
nonmatching slots
Add disks drives as described in
Chapter 2 of this guide.
Installation terminates with
the following message:
FATAL: missing
interconnect hardware
ServerNet CDs used for
Ethernet cluster installation
Use the correct CDs for the configuration
of the cluster.