M0201AA
ION
®
-E Series Hardware Installation Guide
© June 2017 CommScope, Inc.
Page 33
Installing Subracks and PSUs in an Equipment Rack
Figure 3-3
and
Table 3-1
show the internal mapping between CAT Cards and AUT Cards. There is a specific
relationship between the slot in which the CAT and AUT Cards are installed, and the CAT Card and AUT Card
ports. For example:
•
The CAT Card slot/port combination of
L1.1
always maps to AUT Card slot/port combination
M1.1
•
The CAT Card slot/port combination
L4.4
always maps to AUT Card slot/port combination
M2.8
.
This internal mapping provides the Ethernet backhaul for Ethernet devices connected to the Ethernet ports
on the AUT Card.
Figure 3-3.
Example of Internal Mapping of CAT Card Ports to AUT Ports
Use the preceding information and the following steps to connect the AUT Card(s) to the ION-E system.
1
Follow the steps in
"Install the CAN and TEN Cards” on page 27
to install the AUT Card(s) into the WCS
Subrack Slots M1 - M2, as needed for this CAT/TEN installation.
2
Refer to
Figure 3-3
and
Table 3-1
to connect Ethernet cables from the Ethernet devices to the AUT Card's
RJ45 ports.
Table 3-1.
Internal Mapping of CAT Card Slots/Ports to AUT Card Slots/Ports
WCS Slot CAT Port AUT Slot AUT Port
WCS Slot CAT Port AUT Slot AUT Port
L1
1
M1
1
L3
1
M2
1
L1
2
M1
2
L3
2
M2
2
L1
3
M1
3
L3
3
M2
3
L1
4
M1
4
L3
4
M2
4
L2
1
M1
5
L4
1
M2
5
L2
2
M1
6
L4
2
M2
6
L2
3
M1
7
L4
3
M2
7
L2
4
M1
8
L4
4
M2
8