ION
®
-E Series Hardware Installation Guide
M0201AA
Page 30
© June 2017 CommScope, Inc.
Installing Subracks and PSUs in an Equipment Rack
Connect the CAT Cards
1
Follow the steps in
"Install the CAN and TEN Cards” on page 27
to install the CAT Cards into the WCS
Subrack Slots L1 - L4, as needed for this CAT/TEN installation.
2
Use Cat6A cables (23 AWG minimum) to connect up to four UAPs to the CAT Card ports 1 - 4 (one per
port). Whether or not the UAP is cascaded determines how you connect the CAT Card to a UAP, as
described below.
•
Non-Cascaded
UAPS
To connect up to four individual, non-cascaded UAPs to the CAT Card via ports 1 - 4 (one per port).
–
UAP, UAP-N25, and UAP-X: connect the CAT Card port to the UAP Main port.
–
CAP L: connect the CAT Card port to the CAP L Optical Port 1.
An Ethernet device such as a camera can be connected to the AUX port of a UAP if AUT Cards are
installed in the TEN or CAN.
UAP, UAP-N25
UAP-X
CAT Ports 1 - 4 to/from UAP Main port
CAT Ports 1 - 4 to/from CAP L Opcal Port 1
CAP L