Page 14 of 54
INSTRUCTION MANUAL
SGTEL-168
TELECOM LINE SURGE GENERATOR
1912 1 E l T o ro R d
●
Si l vera do, Ca lifo rni a 9 26 76
●
(9 49) 459 -96 00
●
co m-p o wer. com
REV070516
4.0 Setting up the SGTEL-168
In the following sections, guidance is provided pertaining to the external electrical
connections/interconnections of the SGTEL-168 System and accessories. The guidance is
given on a port-by-port basis.
4.1 Input Power Line Ports
WARNING - DO NOT EXCEED THE RELEVANT INPUT POWER SPECIFICATIONS
DETAILED IN SECTION 3.5 AND ON THE REAR PANEL OF THE GENERATOR ITSELF.
4.1.1
SGTEL-168 System Power Input Port
The SGTEL-168 requires the following power
source:
Voltage: 100-250 V
AC
Frequency: 50/60 Hz
Power: 300VA Maximum
In accordance with international safety standards, this instrument is
equipped with a three-wire power cable. When connected to an
appropriate AC power outlet, this cable grounds the instrument frame.
WARNING:
For protection from electrical shock, the power cable
ground must not be defeated.
The power plug must be plugged into an outlet that
provides a protective earth ground connection.
4.1.1.1
System Power Input Port Fuse
To access fuse, insert
the end of a small flat-
blade screwdriver into
the slot as shown in
Figure 4 to open the
compartment.
Replace fuse only with
same type and rating
[250V, 5A (T)]. After
replacing fuse, slide
fuse holder firmly back
into position within its
cavity.
FIGURE 4 -
Accessing the Input Power Fuse