Page 12 of 54
INSTRUCTION MANUAL
SGTEL-168
TELECOM LINE SURGE GENERATOR
1912 1 E l T o ro R d
●
Si l vera do, Ca lifo rni a 9 26 76
●
(9 49) 459 -96 00
●
co m-p o wer. com
REV070516
3.5 Product
Specifications
Output Waveform Parameters
Surge Type
Open Circuit
Voltage -
V
pk
(Volts)
Rise
Time -
T
r
(
μ
s)
Decay
Time -
T
d
(
μ
s)
Short Circuit
Current -
I
pk
(Amps)
Rise
Time - Tr
(
μ
s)
Decay
Time
(
μ
s)
Type A – ±800V
(metallic)
800 - 880
6 - 10
560 - 860
100 - 115
5 - 10
560 - 760
Type A – ±1500V
(longitudinal)
1500 - 1650
6 - 10
160 - 260
200 - 230
5 - 10
160 - 210
Type B – ±1000V
(metallic)
1000 - 1100
9 ±2.7
720 ±144
25 - 27.5
5 ±1.5
320 ±64
Type B – ±1500V
(longitudinal)
1500 - 1650
9 ±2.7
720 ±144
37.5 – 41.3
5 ±1.5
320 ±64
Powerline – ±2500V
(Line to Neutral)
2500 - 2750
1 – 2
10 – 19
1000 – 1250
1 – 2
10 – 19
Monitor Ports
Voltage Monitoring Port (V
mon
)
1000:1
±10%
(V
(actual)
= V
(measured)
* 1000)
Current Monitoring Port (I
mon
)
100:1
±10%
(I = V
(measured)
* 100)
[0.01 Volts/Amp]
Sync Output Port
0-5 V
DC
Electrical
System Power Input
100-250 V
AC (rms)
, 50/60 Hz
(300 VA Max.)
Fuse Type
5 Amps (T)
EUT Power Input
250 V
AC (rms)
(maximum)
, 50/60 Hz
(16A Max.)
100 V
DC
(maximum)
16 Amps up to 48 V
DC
, 10 Amps up to 100 V
DC
Input/Output Connections
EUT Power Input Port
ABB 216B6 16A IP44 Socket Inlet
(mating connector provided)
SGTEL-168 System Power Input Port
IEC C13 Receptacle
EUT Power Output Port
Universal Multi-Configuration AC Socket
Safety Interlock Port
4-pin, 7mm Receptacle
(mating push-pull plug provided)
Fiber Optic Port
Avago Duplex Latching POF jack
(A/B/G) Surge Output Ports
(3) 4mm banana safety sockets
Monitor Output Ports
(3) BNC-type
(female)
Mechanical
Dimensions (H)x(W)x(D)
(4U) 7.75” x 19” x 24.25”
(19.7 x 48.3 x 61.6 cm)
Weight
61 lbs
(27.7 kg)
Environmental
Operating Temperature
40°F to 104°F
(5°C to 40°C)
Cooling
Forced Air
(integral fan)