75
Check the sealing O-Rings and replace them if they are damaged.
Leave the cartridge in the filter when the compressor is not in use.
Maintain a pressure of 40-70 bar inside the filter to prevent outside dampness from getting in.
MODEL
N° OF 10 LITRE CYLINDERS TO
BE REFILLED
VOLUME OF
FILTERED AIR
DURATION OF
THE FILTER
200 bar
300 bar
cu.m.
hours
MCH 8/EM
322
214
644
80
MCH 13/ETC
322
214
644
50
MCH 16/ETC
322
214
644
50
MCH 13/ET
322
214
644
50
MCH 16/ET
322
214
644
50
MCH 13/SH
322
214
644
50
MCH 16/SH
322
214
644
50
MCH 13/DY
222
214
644
50
MCH 16/DY
222
214
644
50
MCH 13/DH
322
214
644
50
MCH 16/DH
322
214
644
50
Table 4
To replace the active carbon filter, proceed as follows:
- unscrew the external cap using a lever between
the screws “A” (Fig. 127);
127
Maintenance
Summary of Contents for MCH 13/DH
Page 93: ...93 13 2 Electricals diagrams Machine diagrams...
Page 94: ...94 Machine diagrams...
Page 106: ...106 153 152 156 155 154 158 097 157 159 160 198 188 187 189 Spare parts Filtering system...
Page 110: ...110 MCH 13 16 ETC Spare parts 006 007 008 009 005 012 013 010 011 002 001 003 004...
Page 112: ...112 MCH 13 16 ET Spare parts 006 007 008 009 005 012 013 010 011 002 001 003 004 015 014 016...
Page 114: ...114 MCH 8 EM Spare parts 006 007 008 009 017 012 013 010 011 002 001 003 004 015 014 016...
Page 116: ...116 MCH 13 16 SH Spare parts 006 007 008 009 018 012 013 019 020 002 001 003 004...
Page 118: ...118 MCH 13 16 DY Spare parts 015 014 003 004 002 001 022 023 009 016 007 008 021 006 012 013...