73
The filter must be replaced every 125 operating
hours with the following procedure:
MCH 13-16/ETC Standard
1
Remove the protection guard by unscrewing
the fastening screws (Fig. 124).
NOTE: for all the other models it is not necessary
to remove the protection guard.
2
Press cap n° 1 lightly and turn it in an anti-
clockwise direction (Fig. 125).
MCH 13-16/ETC Standard
124
The intake filter must be checked to make sure it is in good order every 25 operating hours.
The filter is cleaned by blowing air inside the cartridge when it has been removed.
Replace the cartridge turning it by 60° compared to its initial position.
11.5
Air intake filter
125
Maintenance