5. HYDRAULIC CONNECTIONS (fig. 2 and 3) 

Before proceeding with hydraulic connection it is essential to install a non-return valve in the pump´s inlet. 
The SPEEDMATIC 

Easy

 must be connected in vertical position (diag.3), the inlet port ( G1 1/4” male) directly to the main pump discharge and 

the outlet port (G 1 1/4” male) at the main network. 
It is compulsory to use an hydropneumatic tank in order to avoid continuous start-stops due to the deterioration of taps, valves, ... and also to 
prevent "water hammer" in installations with valves of wide diameter.

6. ELECTRIC CONNECTION (fig. 1)
Before doing manipulations inside the device, it should be disconnected of the electric supply and after disabling, wait 
for 2 minutes in order to avoid electrical discharges.

n

Use cables type H07RN-F with section enough to the power installed:

2

2

n

 Power supply: s 

á

 1,5 mm (max.2,5 mm ).

2

2

n

 Motor supply:  s 

á

 1 mm  (max.2,5 mm ) depending on the cable length (see fig.1).

n

Verify if the power supply is 220/240 V. Dismount the back cover and carry out the connections according to the indications of fig. 1.

n

Do  the  power  supply  connection  (being  sure  there  is  a  good  earth  connection): 

L1  L2   

Do  the  connection

 

by  mean  of 

 

magnetothermic switch in OFF mode.

n

The earth conductor must be longer than the others. It will be the first one to be mounted during the assembly and the last one The 
earth conductor must be longer than the others. It will be the first one to be mounted during the assembly and the last one to 
disconnect during disassembling.

n

Do the pump connection. 

n

Min. level control (optional). There is an input for stopping the pump as soon as is disconnected the external switch of minimum level.

2

    Connection of 2 devices (optional): for the communication of 2 devices it will be used a cable of 4x0.25 mm , it will be inserted throw 

the PG cable gland located in the bottom/lateral of the device. See Fig.9.

WARNING! Wrong connections could spoil the electronic circuit. The manufacturer declines all responsability  in damages 
caused by wrong connection. 

7. CONTROL PANEL .

1 - 

2-DIGIT DISPLAY

 . In 

AUTOMATIC 

mode it shows instantaneous pressure (bar), instantaneous current comsumptions (A) and 

minimum speed (Hz).

2 - 

MANUAL START-STOP

 pushbutton. It allows to start and stop manually the pump.

3 - Pushbutton 

MENU

 for enter or quit the menu.

4 - With these  pushbuttons we can increase or dicrease programming values showed in the screen (1).
5 - 

ENTER

 for saving programmed values. Every pulsation is succeeded by a new field of the 

CONFIGURATION MENU

Whenever we want to quit the configuration sequence press 

MENU

 (3).

6 - Led lights:

• 

LINE

 green: Electric supply. Bright when it is connected.

• 

FAILURE

 red: Bright or flashing depending on type of failure.

• 

PUMP

 yellow: When it is bright  means pump working. It is lit with the pump stopped or when the device is not connected.

• 

AUTOMATIC

 green: it is bright in AUTOMATIC mode. When it is intermittent in MASTER&SLAVE mode it means that this device will 

be auxiliary in the following cycle. 

7 - Pushbutton 

ON/OFF

: It allows to change from 

AUTOMATIC

 to 

MANUAL

 mode or vice versa.

 8. START UP (plug&play). 

n

 Be sure that the pump is correctly primed

n

Connect the SPEEDMATIC 

Easy

  to the electric supply with the magnetothermic switch, all the led lights will flash instantaneously for 

a second. Screen will show 

SP

 (set pressure) and then its default value 

2,0 

bar, both displays are alternated in time periods of 1"/5" .

n

By mean of 

pq

 we can adjust the desired set pressure.

n

Press the push-button 

AUTO

, the device will start to operate and led light 

AUTO ON/OFF 

will light. The screen will show the 

instantaneous pressure. Being in automatic mode and using the push-buttons we can change the display:

n

P: instantaneous pressure (bar).

n

Fr: instantaneous speed.

n

A: instantaneous current consumption.

P

UM

P

ON

START

STOP

OFF

-9-

M

Summary of Contents for Speedmatic Easy 06MT

Page 1: ...TION AND OPERATING INSTRUCTIONS ISTRUZIONI D INSTALLAZIONE E USO INSTRUCTIONS POUR L INSTALLATION ET L EMPLOI INSTRUCCIONES PARA LA INSTALACI N Y UTILIZACI N MONTAGE UND GEBRAUCHSANLEITUNGEN EN IT FR...

Page 2: ...es consequence des gouttements par d t riorations in vitables de robinets valves etc ainsi que poyr viter le marteau de l eau produits mormalment par electrovalves ou valves avec un pas de d bit consi...

Page 3: ...RATION CE DE CONFORMIT 12 ALARMES INSTRUCCIONES PARA LA INSTALACI N Y UTILIZACI N 20 23 1 FUNCIONAMIENTO 2 CLASIFICACI N Y TIPO 3 CARACTERISTICAS GENERALES 4 CARACTER STICAST CNICAS 5 INSTALACI N HIDR...

Page 4: ...TO CORPO Easy CONNEXIONS DU CORPS Easy CONEXIONES CUERPO Easy ELEKTRISCHE ANSCHL SSE u w v L m 5 25 1 5 25 50 u Class C2 4 MAX MIN LEVEL CONNECTION COLLEGAMENTO LIVELLO CONNEXION NIVEAU CONEXION NIVEL...

Page 5: ...on generale Alimentazione elettrica v 2 S mm 2 5 1 4 L m 5 25 1 5 25 50 u u v Three phase motor connection Collegamento motor tre fasi Connexion motor triphas e Conexi n motor trif sico Dreiphasen Mot...

Page 6: ...A Los accesorios w x yy son recomendables pero no imprescindibles B En el caso del tanque hidroneum tico se recomienda su utilizaci n en instalaciones donde se pretenda evitar el golpe de ariete HINWE...

Page 7: ...to Avviti la copertura e la PG ES 1 Desatornillar la tapa y aflojar el PG pasacables situado en su base 2 Introducir el cable de comunicaciones a trav s del PG 3 Sacar la regleta de conexiones de su a...

Page 8: ...Control circuit for alternating current motor with power factor cos 0 6 Pollution Degree 2 Rated impulse voltage 2500V CATII Class of disconnection 1Y electronic disconnection 3 MAIN CHARACTERISTICS n...

Page 9: ...throw the PG cable gland located in the bottom lateral of the device See Fig 9 WARNING Wrong connections could spoil the electronic circuit The manufacturer declines all responsability in damages caus...

Page 10: ...as 2 SLAVE ENTER to validate 7 In case 1 MASTER is selected it can be ajusted a maximum time of continued functioning After the configurated time t A of a continued functioning an alternance will be f...

Page 11: ...r could be blocked Verify intensity values introduced in the configuration menu Once the problem have been solved the operation will be restored going to the SET UP menu see the chapter configuration...

Page 12: ...in ausiliare la sua pompa la seconda in avviarsi e cos successivamente Cio il fatto che un dispositivo stia configurato come MASTER implica il controllo del gruppo per questo non impedisce che funzio...

Page 13: ...struzioni fig 9 ATTENZIONE I collegamenti erronei possono danneggiare irrimediabilmente il circuito elettronico 7 PANNELLO DI COMANDI 1 Schermo 2 digiti Nella situazione di lavoro pu indicare la press...

Page 14: ...e lo Slave come 2 SLAVE ENTER per convalidare 7 Nel caso che sia selezionato 1 MASTER si pu regolare un tempo massimo di funzionamento continuo Dopo il tempo configurato t ALT di funzionamento continu...

Page 15: ...adeguato Una volta risolto il problema di detta pompa per restabilire il suo funzionamento si andr sul menu INSTALLAZIONE vedere confugurazione e introdurre i valori di intensit adeguati A3 POMPA CAN...

Page 16: ...nt comme dispositif auxiliaire 2 CLASSIFICATION ET TYPE Selon EN 60730 1 l quipe est un dispositif d assemblage ind pendant du type 1B avec software de classe A Circuit de commande moteur pour courant...

Page 17: ...lisera un c ble du type 4x0 25 mm qui sera introduit par le PG des c bles situ dans la partie inf rieure de la couverture du dispositif Voir fig 9 ATTENTION Le fabricant d cline toute responsabilit ca...

Page 18: ...lage de groupe M S l appareil ma tre doit tre configur comme 1 MASTER et l esclave comme 2 SLAVE ENTER pour valider 7 Dans le cas o 1 MASTER est s lectionn c est possible de r gler un temps maximum de...

Page 19: ...me pour r tablir son fonctionnement il faudra aller au menu INSTALLATION voir configuration et introduire les valeures d intensit correctes A3 POMPE DEBRANCHEE Alarme d finitive DESCRIPTION le Speedma...

Page 20: ...l ciclo siguiente se convierte en auxiliar su bomba es la segunda en ponerse en marcha y as sucesivamente Por lo tanto el hecho que un dispositivo est configurado como MASTER implica el control del gr...

Page 21: ...ables situado en la parte inferior de la tapa del dispositivo Ver fig 9 ATENCION Las conexiones err neas pueden da ar irremediablemente el circuito electr nico El fabricante no se responsabilizar de l...

Page 22: ...s para el dispositivo que pretendamos configurar como 2 SLAVE Al pulsar ENTER validamos y salimos del men de configuraci n 7 En modo 1 MASTER En caso de no finalizar un ciclo por consumos continuados...

Page 23: ...Verificar que los datos introducidos en el menu de configuraci n respecto el consumo de la bomba sea el adecuado Una vez solucionado el problema para restablecer el funcionamiento de la bomba se deber...

Page 24: ...KLASSIFIKATION UND TYP Gem EN 60730 1 ist das Ger t eine Vorrichtung f r die selbst ndige Montage vom Typ 1B und ist mit Software der Klasse A ausgestattet berwachungsstromkreis f r den Wechselstromm...

Page 25: ...rnimmt keine Haftung f r Sch den am Ger t die auf einen fehlerhaften Anschluss zur ckzuf hren sind 7 STEUERTAFEL 1 Display mit 2 Ziffern W hrend des Betriebs k nnen der aktuelle Druck bar die aktuell...

Page 26: ...e ber die Pfeiltasten den gew nschten Nennwert der Stromst rke f r die Pumpe ein um den thermischen Schutz zu aktivieren F r das Ger t Easy09 MM ist ein Wert zwischen 0 und 9 A einzugeben Der standard...

Page 27: ...ebung der St rungsursache muss f r die neuerliche Inbetriebnahme der Pumpe ber das entsprechende Men feld Zugriff auf die EINSTELLUNG ausge btunddieerforderlichenStromst rkewerteeingegebenwerden A3AUS...

Page 28: ...e europee armonizzate UNE EN 60730 1 1998 A11 1998 A2 1998 A14 1998 A15 1998 A20 1998 A17 2001 ERRATUM A1 2001 A18 2003 UNE EN 60730 2 6 1997 A1 1998 A2 1999 CORR A1 2001 CORR A2 01 UNE EN 61800 3 Cla...

Reviews: