Alternative ground for fibre glass hulls
C-8
Appendix C: Ground and RF protection
98-148248-C
C.5 Alternative ground for fibre glass hulls
C.5.1 To ground the ACU
To ground the ACU do as follows:
1. Preferably ground the ACUwith the short ADU cable and a grounding kit (available from
Thrane & Thrane A/S).
2. Ground the ACU at its grounding stud in order to ensure a proper grounding if the short
ADU cable is disconnected.
3. You must establish the ground connection at a dedicated RF ground (either capacitive
or electrical coupled).
C.5.2 To ground the ADU
To ground the ADU do as follows:
1. If the mounting base of the ADU is electrically connected to any other ground potential
than the ACU (e.g. Lightning Ground), you must isolate the ADU at its mounting bolts
with shoulder bushings and washers - see section C.6.3 .
2. However, you must establish a ground connection via one of the mounting bolts with a
separate ground cable.
3. You must route the ground cable in parallel and in close proximity to the shielded coax
cable hence connecting the ADU to the ACU Grounding kit. Use a heavy gauge wire
with tinned strands (min. 6 mm
2
) for this purpose.
Important
Bear in mind that the ADU ground connection is to be
made at the
same electrical ground potential
as
the ACU (see
).
Figure C-5: Alternative grounding for fibreglass hulls
Summary of Contents for SAILOR 60 GX
Page 1: ...Cobham Public SAILOR 600 VSAT Ka SAILOR 600 VSAT Ka High Power Installation manual...
Page 116: ...Software update 8 12 Chapter 8 Service 98 148248 C Figure 8 11 Verifying software update...
Page 181: ...Telenor antenna approval G 4 Appendix G Approvals 98 148248 C...
Page 192: ...98 148248 C www cobham com satcom Cobham Public...