67
8. MAIN - Measured values
In the "Measured values" menu, the most important welding relevant
values are displayed.
The displays V (Volt) and A (Ampere) show the voltage and current actual
value during the welding process.
The "Hold" function switches the display for V or A from ACTUAL values to
Hold values. The Hold value display shows the averaged values for the last
weld.
Different parameters are shown, depending on the selected process and
the sensors used. The example in Figure 24 shows the pulse process.
8.1 Operating data
For the cost control and calculation purposes, the menu "Measured values"
provides the submenu "Operating data". Before determining the consump-
tion costs, the current values for wire weight, wire costs, gas costs and
energy costs must be entered in the "Cost rates" menu item.
The numerical values are selected by means of rotary knob 3. By pressing
the rotary knob 3, you can modify the adjustment speed (x10, x100, x1000).
Meaningful operating data can only be collected in conjunction with the
optional SD sensor in the wire drive. The operating data can be displayed
on the operating module or evaluated in conjunction with the "QDM" soft-
ware and stored on an external data carrier.
Puls 4 -Takt
V
0
A
1.2 mm Fe
82% Argon 18% Co
2
0.0
Hold
0.0
0
V
A
Hold
0.0
Leistung
Pulsspannung
Grundspannung
0.0
0.0
kW
V
V
Betriebs
daten
Puls 4 -Takt
V
0
A
1.2 mm Fe
82% Argon 18% Co
2
0.0
Hold
0.0
0
V
A
Hold
0.0
Leistung
Pulsspannung
Grundspannung
Leistung
Pulsspannung
Grundspannung
0.0
0.0
kW
V
V
Betriebs
daten
Figure 24. Menu measured values with switched on Hold function
INFO!
Summary of Contents for QINEO
Page 4: ......
Page 10: ......
Page 11: ...11 Operational safety Block 1 Operational Safety...
Page 29: ...29 Block 2 Basic information Qineo Champ Pro...
Page 42: ...CHAMP Pro 42...
Page 109: ...109 Block 4 Additional information...
Page 124: ...124 SD module...
Page 138: ...138 Commissioning 6 7 8 5...
Page 140: ...140 Commissioning 7 5 6 The wire inlet must not touch the wire drive roller INFO...
Page 145: ...145 Block 6a Error messages...
Page 159: ...159 Block 6b General maintenance instructions...
Page 164: ...164...
Page 165: ...165 Block 7 Automation...
Page 184: ...184...
Page 185: ...185...
Page 186: ...www qineo de...