No.
Error message on the
display
Possible cause
Remedy
28
Error charging circuit on
Tronic Pulse
Check cable connection between
charging circuit and control
computer.
Service
29
Calibration error
Inverter
Zero point adjustment cannot be
executed. Values too high. Internal
check failed.
Switch machine Off and On
Service
30 Excess temperature fan
Ambient temperature too high or
fan faulty.
Check air passage and if necessary check
filter mat
Service
31
Excess temperature
transformer
Ambient temperature too high in
connection with too high welding
capacity or faulty transformer.
Check air passage and if necessary check
filter mat
Service
32
Excess temperature
rectifier
Ambient temperature too high in
connection with too high welding
capacity or faulty rectifier.
Check air passage and if necessary check
filter mat
Service
33
Excess temperature
power unit
Ambient temperature too high in
connection with too high welding
capacity or faulty power supply
unit.
Check air passage and if necessary check
filter mat
Service
34
Excess temperature
water pump
Ambient temperature too high
or pump runs without coolant
or coolant circuit is interrupted,
possibly pump faulty.
Let the machine cool down
Check cooling circuit
Refill coolant
Service
35 Overcurrent inverter
Mains current consumption
exceeded.
Switch machine Off and On
Service
36
Wrong input voltage
from inverter
Mains voltage monitoring exceeded.
Mains voltage fluctuations.
Check mains voltage
Service
37
Duty cycle exceeded
(inverter)
The output currents listed in the
technical data or on the type plate
were exceeded.
Weld with lower current at the same
duty cycle
Weld with the same current at a lower
duty cycle
38 General inverter error
Hardware error.
Service
39
Robot software version
out-of-date
Software update required.
Software update
Service
40
Power unit supply
voltage too low
Hardware error.
Service
41
Software version remote
control out-of-date
Software update required.
Software update
Service
42
Software version SD
module out-of-date
Software update required.
Software update
Service
43 SD module failed
Connection is interrupted or SD
module faulty.
Possibly software version SD
module out-of-date.
Switch machine Off and On
Check plug and connections
Software update
Service
Summary of Contents for QINEO
Page 4: ......
Page 10: ......
Page 11: ...11 Operational safety Block 1 Operational Safety...
Page 29: ...29 Block 2 Basic information Qineo Champ Pro...
Page 42: ...CHAMP Pro 42...
Page 109: ...109 Block 4 Additional information...
Page 124: ...124 SD module...
Page 138: ...138 Commissioning 6 7 8 5...
Page 140: ...140 Commissioning 7 5 6 The wire inlet must not touch the wire drive roller INFO...
Page 145: ...145 Block 6a Error messages...
Page 159: ...159 Block 6b General maintenance instructions...
Page 164: ...164...
Page 165: ...165 Block 7 Automation...
Page 184: ...184...
Page 185: ...185...
Page 186: ...www qineo de...