Model 21 -CET-8 Service Manual Page 69
Figure 5-3. Water Flo
w
Comparison
Switching the ON/OFF switch to OFF removes power from most of the 120
VAC circuit components, and activates the 3-minute timer. The following
circuit operations occur.
1
.
The transformer and high voltage circuits on the line side of the heater
contactor remain energized.
2. The red indicator light on the ON/OFF switch turns OFF.