Page 34
Model 21 -CET-8 Service Manual
CAUTION
Steam leaks around the door, cooking compartment flooding,
reduced cooking performance, and compartment implosion
can be caused by a blocked drain or drain screen. Inspect and
clean the drain and drain screen before each use. Never
operate the steamer without the screen in place.
Inspect the Cooking Compartment
At the back of the cooking compartment, the drain is covered by a moveable
drain screen. Refer to Figure 3-4. The screen prevents large food particles
from entering and blocking the drain line. Any blockage of the drain line or
screen can reduce drainage from the cooking compartment resulting in
reduced cooking performance, equipment damage, and a hazard to the
operator. A blocked or slow drain may cause:
• Hot water to collect in the compartment and spill out when the
compartment door opens.
• Pressure fluctuations in the compartment, resulting in steam leaks around
the door gasket, or compartment implosion.
• Reduced convection in the compartment, reducing cooking performance.
Figure 3-4. Compartment Drain Screen
Printed 12/90
Power ON (Automatic Fill)
When the SteamCraft 3.1 is turned on, it automatically fills the steam
generator with water. Use this procedure at the beginning of a shift to prepare
the steamer for operation without starting steam generation. When ready to
start steam cooking, begin either the Timed or Manual Operating Procedure.
1. At the beginning of this procedure the ON/OFF switch is in the OFF
(bottom) position. The control panel circuits are not powered and the timer
display is blank.
2 Press the TIMED (top) end of the TIMED/MANUAL switch.
3. Press the ON (top) end of the ON/OFF switch to energize the SteamCraft
3.1 control panel. The red indicator on the switch lights, and water fills the
steam generator.
4. During the fill cycle, check the timer display. If the timer is not zeroed
(00:00), clear the timer by pressing and holding the CLEAR key on the
key pad control panel
5. When the generator
is full, the SteamCraft 3.1 automatically stops water
flow.
Summary of Contents for steamcraft 21-CET-8
Page 9: ......
Page 53: ...Model 21 CET 8 Service Manual Page 45 Printed 12 90 ...
Page 104: ...Model 21 CET 8 Service Manual Page 97 Printed 12 90 ...
Page 109: ...Figure 6 1 Major Component Groups Printed 12 90 ...
Page 112: ...Page 106 21 CET 8 Service Manual Figure 6 3 Steamer Compartment Group Printed 12 90 ...
Page 114: ...Figure 6 4 Compartment Door And Hinge Assemblies Printed 12 90 ...
Page 120: ...Page 114 21 CET 8 Service Manual Figure 6 7 Electrical Components Assembly Printed 12 90 ...
Page 122: ...Figure 6 8 Steam Generator Assembly Printed 12 90 ...
Page 124: ...Figure 6 0 Heater Assembly Printed 12 90 ...
Page 130: ...Figure 6 11 Water Inlet System Printed 12 90 ...
Page 132: ...Figure 6 12 Condenser And Drainage Systems Printed 12 90 ...
Page 134: ...Figure 6 13 Equipment Stand Printed 12 90 ...
Page 136: ...Figure 6 14 SteamCraft 3 1 Wiring Diagram Electronic Time Printed 12 90 ...
Page 137: ...Figure 6 15 SteamCraft 3 1 Schematic Diagram Electronic Timer Printed 12 90 ...
Page 138: ...Figure 6 16 SteamCraft 3 1 Wiring Diagram Mechanical Timer Printed 12 90 ...
Page 139: ...Figure 6 17 SteamCraft 3 1 Schematic Diagram Mechanical Timer Printed 12 90 ...