Model 21 -CET-6 Service Manual Page 25
5. When the TIMED/MANUAL switch is set to MANUAL, the steam
generating cycle starts. Start timing upon pressing the MANUAL
end of the TIMED/MANUAL switch. Check and time the following
functions.
• Immediately:
The condenser solenoid clicks open and condenser
flow starts. With the float cylinder water level above one inch, the
heater coil turns on.
• After
2-5 seconds:
A small stream of water flows from the drain
pipe. If no drain water flows, check that the water supply valves are
open.
• After 2 minutes:
A dull roaring sound indicates the beater is working
and the unit is beginning to generate steam.
• After
3-5 minutes:
Steam begins to enter the compartment from the
nozzles. A small quantity of water may drip from the nozzles until
steam clears the lines.
• After 4-6 minutes:
Steam from nozzles begins to fill compartment
6. When the TIMED/MANUAL switch is set to TIMED(timer zeroed),
the steam generating cycle stops. Press the TIMED end of the
TIMED/MANUAL switch.
• Immediately:
The heaters turn off, and the condenser flow stops.
• After about 30 seconds:
Steam stops entering the cooking
compartment.
7. Open the cooking compartment door to vent the steam and allow the
compartment to cool slightly. After 2 or 3 minutes, close the door
and continue testing.
8. With the TIMED/MANUAL switch set to TIMED, use the timer key
pad to set the timer for 10 minutes. Press the number keys 1 0 0 0
in sequence. The display reads 10:00 (ten minutes and zero
seconds).
9. When the START/STOP key is pressed, the steam generating cycle
starts. This is the same sequence observed in steps 5 and 6,
except:
• The electronic timer controls the cycle.
• The elapsed times are shorter because the water in the steam
generator and the cooking compartment were preheated during
step 5.
• The electronic timer automatically starts the step 6 functions after
counting down to zero.
10. Press the START/STOP key and observe the following steam
generating functions.
a. The timer display changes to PAUS until the cooking
compartment reaches cooking temperature. When it does, the
timer begins counting down to zero.
b.The condenser solenoid clicks open and condenser flow starts.
A small stream of water flows from the drain pipe.
Printed 12/90
Summary of Contents for steamcraft 21-CET-8
Page 9: ......
Page 53: ...Model 21 CET 8 Service Manual Page 45 Printed 12 90 ...
Page 104: ...Model 21 CET 8 Service Manual Page 97 Printed 12 90 ...
Page 109: ...Figure 6 1 Major Component Groups Printed 12 90 ...
Page 112: ...Page 106 21 CET 8 Service Manual Figure 6 3 Steamer Compartment Group Printed 12 90 ...
Page 114: ...Figure 6 4 Compartment Door And Hinge Assemblies Printed 12 90 ...
Page 120: ...Page 114 21 CET 8 Service Manual Figure 6 7 Electrical Components Assembly Printed 12 90 ...
Page 122: ...Figure 6 8 Steam Generator Assembly Printed 12 90 ...
Page 124: ...Figure 6 0 Heater Assembly Printed 12 90 ...
Page 130: ...Figure 6 11 Water Inlet System Printed 12 90 ...
Page 132: ...Figure 6 12 Condenser And Drainage Systems Printed 12 90 ...
Page 134: ...Figure 6 13 Equipment Stand Printed 12 90 ...
Page 136: ...Figure 6 14 SteamCraft 3 1 Wiring Diagram Electronic Time Printed 12 90 ...
Page 137: ...Figure 6 15 SteamCraft 3 1 Schematic Diagram Electronic Timer Printed 12 90 ...
Page 138: ...Figure 6 16 SteamCraft 3 1 Wiring Diagram Mechanical Timer Printed 12 90 ...
Page 139: ...Figure 6 17 SteamCraft 3 1 Schematic Diagram Mechanical Timer Printed 12 90 ...