Page 94
Model 21 -CET-8 Service Manual
Heater Contactor
1. Set the voltmeter to the 250 VAC scale.
2. Set the ON/OFF switch to the ON position.
3. Set the TIMED/MANUAL switch to the MANUAL position. Operate the SteamCraft
3.1 for about 10 minutes, or u ntil it is steaming continuously, and the water in the
float cylinder is at operating level.
4. Refer to Figure 5-22, and check for 120 VAC across the heater contactor coil
terminals.
• If the meter reads 120 VAC across the test points, and the heaters are hiring
the heater contactor is good. End this procedure here.
• If the meter reads 120 VAC across the test points, and the heaters are not
heating continue this procedure with step 5.
• If the meter reads 0 VAC or a low voltage across the test points, the fault is not
in the heater contactor.
a. Check the black, white/black, brown, and white/brown wires connected to
the heater contactor for continuity and secure connections. Replace or
repair faulty wiring and connections.
b. Test
the high temperature lim it switch.
c. Test the float low level switch.
d. Test the TIMED/MANUAL switch.
5. Set the voltmeter to the 500 VAC scale. Refer to Figure 5-22, and check the
voltage across the contact pairs.
• If the meter
reads 230 VAC across one or more contact pairs , replace the
heater contactor.
• If the meter reads 0 VAC across all contact pairs, the fault is not in the heater
contactor.
a. Check the wires and connections from the contact pairs to the heater
elements for continuity and secure connections. Replace o r repair faulty
wiring and connections.
b. Check the wires and connections from the terminal block to the contacts for
continuity and secure connections. Replace or repair faulty wiring and
connections.
c. Test heater elements.
Printed 12/90
Summary of Contents for steamcraft 21-CET-8
Page 9: ......
Page 53: ...Model 21 CET 8 Service Manual Page 45 Printed 12 90 ...
Page 104: ...Model 21 CET 8 Service Manual Page 97 Printed 12 90 ...
Page 109: ...Figure 6 1 Major Component Groups Printed 12 90 ...
Page 112: ...Page 106 21 CET 8 Service Manual Figure 6 3 Steamer Compartment Group Printed 12 90 ...
Page 114: ...Figure 6 4 Compartment Door And Hinge Assemblies Printed 12 90 ...
Page 120: ...Page 114 21 CET 8 Service Manual Figure 6 7 Electrical Components Assembly Printed 12 90 ...
Page 122: ...Figure 6 8 Steam Generator Assembly Printed 12 90 ...
Page 124: ...Figure 6 0 Heater Assembly Printed 12 90 ...
Page 130: ...Figure 6 11 Water Inlet System Printed 12 90 ...
Page 132: ...Figure 6 12 Condenser And Drainage Systems Printed 12 90 ...
Page 134: ...Figure 6 13 Equipment Stand Printed 12 90 ...
Page 136: ...Figure 6 14 SteamCraft 3 1 Wiring Diagram Electronic Time Printed 12 90 ...
Page 137: ...Figure 6 15 SteamCraft 3 1 Schematic Diagram Electronic Timer Printed 12 90 ...
Page 138: ...Figure 6 16 SteamCraft 3 1 Wiring Diagram Mechanical Timer Printed 12 90 ...
Page 139: ...Figure 6 17 SteamCraft 3 1 Schematic Diagram Mechanical Timer Printed 12 90 ...