background image

INSTALLATION INSTRUCTIONS AND HOLE-CUTTING TEMPLATE 

MANROSE

® 

BATHROOM HEATER 

WITH EXTRACTION FAN AND LED LIGHTS 

FAN5876 

Dear Customer, 

Thank you for selecting our MAN ROSE Bathroom Heater-Fan-Light unit. 

Please read all instructions before commencing installation. 

IMPORTANT: This unit must be installed to comply with the appropriate council regulations and the Australia and New 

Zealand wiring rules AS/NZS3000:2000 or latest edition thereof. 

The mains supply and interconnecting cables required for installation of this unit are not included. 

WARNING - ALL WIRING MUST BE CARRIED OUT BY A REGISTERED ELECTRICIAN 

1.

Use this bathroom heater-fan-light unit only as described in this manual. Any other use not recommended by the

manufacturer may cause fire, electric shock, or injury to persons. If you have questions, contact the manufacturer

or local agent.

2.

All wiring must be carried out by a licensed electrician in accordance with all national wiring codes.

3.

Make sure the power is isolated before installing.

4.

The bathroom heater-fan-light unit must be properly earthed.

5. The heater's glass shield is hot when in use. Do not touch the heat lamp or glass shield when in use.

6. For the purpose of avoiding any dangerous gas leaking into your bathroom, the ducting of the bathroom

heater-fan-light unit must not be shared with the ducting of air-fueled water heater or other open-fire appliances in

the same flue.

7.

The bathroom heater-fan-light unit must be isolated from the power by means of a plug or a switch capable of

disconnecting all poles with a contact separation of at least 3mm in each pole.

8. The power cable must be rated for a minimum 1 0A inductive load.

9. The appliance is not intended for use by persons (including children) with reduced physical, sensory or mental

capabilities, or lack of experience and knowledge, unless they have been given supervision or instruction

concerning use of the appliance by a person responsible for their safety.

10. Children should be supervised to ensure that they do not play with the appliance.
11. The bathroom heater-fan-light unit is to be installed so that switches and other controls cannot be touched by a

person in the bath or shower.

12. The appliance shall, under no circumstances, be covered with insulating material or similar material.

13. Regulations concerning the discharge of air have to be fulfilled.

14. Joists, beams and rafters shall not be cut or notched to install the appliance.

IMPORTANT CONSIDERATIONS BEFORE INSTALLING 

A few minutes of planning can make a big difference to the installation time and ultimate satisfaction with the functioning 

of the unit. 

1.

The unit should not be installed directly above a shower or bathtub. The unit must not be installed in a position

where water may splash onto the unit.

2.

The unit is designed for installation in flat ceilings only. Do not mount it on a sloping ceiling or a vertical wall.

3.

The bathroom heater-fan-light is most effective when you are standing directly beneath it, so generally the unit

would be mounted above a place where you would stand to dry yourself.

4.

For the exhaust fan to work efficiently, replacement air of a volume equivalent to what is being extracted must be

able to enter the room. Generally this air would be drawn under the door. If the room is airtight, the fan will not

exhaust air efficiently.

5.

Before commencing any cutting, check in the ceiling space that there are no obstructions such as ceiling joists and

that there is sufficient height clearance for the housing. Check that the electrical wiring can be routed from the wall

switches to the mounting location.

INSTALLATION 

1. Locating the bathroom heater-fan-light unit

For the purpose of obtaining the best heating effect from the lamps

there should be at least 2.1 m overall height from unit to ground.

2. Prepare the ceiling

Select the mounting position for the unit. Check that it is possible to

route the ducting from the unit to the outside of the house. This will

generally be to the soffit but can be to a wall outlet location

(as pictured).

Use this hole-cutting template to mark the hole on the ceiling. Make

sure a distance between the edges of the unit and wall is no less than

250mm. There should be a minimum 220mm vertical distance between

the ceiling and roof.

3. External Grille

Locate the position for the external grille and cut a 155mm diameter

hole. Connect one end of the 150mm diameter duct to the spigot of

the external grille. A 150mm diameter eggcrate grille is included in the

kit to be used when installing into the soffit. If installed in the wall, a

weatherproof cowl should be used. Seal the grille, or cowl, with

suitable sealant.

Note: 

Since the length of each duct is 3.0m, make sure the centre of

the installation hole is no more than 3.0m from the vent.

Note: 

In order to get an effective ventilation, it is suggested that the

duct is no more than 3.0m in length.

4. Remove the fascia

- Remove 4 silicon clips at 2 ends of the rectangle air inlet grilles.

- Remove the screws hidden inside. Remove the fascia.

Note: 

Be careful while removing the screws so that the fascia does not 

drop to the ground. 

5. Remove the lamps

Remove the 4 LED lamps from the heater unit. 

- Remove the halogen heat lamp from the heater unit and keep it in

a safe place. Do not touch this lamp with your bare skin.

Natural skin oils and salts damage new halogen lampsa and 

shorten their life. 

Only handle a new heat lamp with soft, dry, clean, 

lint-free cloth or paper. You can wear gloves, cover your fingers or 

wrap the heat lamp until it is installed (so long as you 

remove all cloth or paper when finished). 

6. Wiring

- Connect one end of the interconnecting wire to

the wall switch panel, and bring the other end

out of the hole in the ceiling.

/1----�� .......... � 

/I'-.,. __ _ 

Heater Unit, 

duct clip 

bathroom 

\  fascia 

ceiling joist  ceiling 

- Remove the terminal block cover on the unit's

housing, make the connection as per the wiring

diagram instruction below, then replace the

terminal block cover. Press excess wire back

into the ceiling.

8  Thermal Protection Unit 

o----i==:::::j....____J

Note: 

Ensure that the power is isolated before 

carrying out any work on electrical installations. 

M  Motor 

C  Capacitor 

LED  Lamp 

IR  Halogen 

L

o-----l<Y-o-1-----' 

Read and save these instructions! 

Please take this card as hole cutting template 470mm x 320mm. 

INSTALLATION INSTRUCTIONS AND HOLE-CUTTING TEMPLATE 

7. Fit the in-house end of the duct to the fan outlet and fix the end with duct clip.

A backdraft stopper is included in the package, fit the stopper to the fan outlet and fix it with one duct clip. Fit the
in-house end of the duct to the stopper, and fix the end with another duct clip.

Note: 

Keep the route as straight as possible.

8. Fixing the unit securely - Two Options.

Choose an optimal direction to put the housing into the hole in accordance with the position of fan outlet. There
are two options for fixing the unit securely and safely to the ceiling. The Unit must be held securely on all 4 sides.
1. The Preferred option is to fix the unit with screws onto Timber supports (not supplied). Installer may need to add
supports on 2 sides in between joists or even build a custom made timber frame for best results.
2. Alternatively, use the 8 x plaster fixing clips provided to secure to 10mm plaster board, see below.

� ""' '", � �, ""�>"�,'", '� ',,,'� '",

bathroom heater 

>22omm 

'Eifuh 

ceiling joist 

1

"'.

Omm

\1

1

::.:••/X\•v 

'•ceiling\ 

'

-

- \  100mm minimum clearance

\

,, 

is required near all ceiling joists 

Reflector 

9. Final Installation

- Install the heat lamp.

Fit one end of the heat lamp into socket and gently push it away from the other socket. When there is enough

room, fit the other end of the heat lamp into its socket (The heat lamp is half coated with a white reflector.

When you grasp the heat lamp with cloth or paper, face the back of the reflector to the ceiling so you can see

the heat lamp's filament. Not doing this will reduce performance)

Reinsert the 4 x LED lamps.

Check the glass shield to make sure that it is not damaged and is well fixed on the fascia by the screws (a little

movement of the glass won't cause any problem to the use)

Replace the fascia with screws. Use 4 silicon clips to cover the screws.

Fix the switch panel to the wall.

Note: 

The switch wiring should be mounted inside the wall to give the switch an integrated built in appearance. 

If it is necessary to run the wiring on the outside of the wall, use a suitable conduit and fixings to properly 

located and hold the wiring used. 

USE 

Our bathroom heater-fan-light unit uses the halogen heat lamp as a source of heat. It also combines the functions of 

exhaust and light. 

1. Heat

'HEAT' switch On/Off

Note: 

Do not touch the heat lamp grill with any part of your body when in use.

2. Exhaust

'FAN' switch On/Off

This unit can exhaust odours and steam in a quick and efficient way by turning on the "FAN" button.

3. Lighting

'Light' switch On/Off

Note: 

Do not switch on/off frequently when in use. Shut off the power if in long periods of inactivity. 

MAINTENANCE 

1. Clean

1) Shut off the power before cleaning.

2) Wipe glass shield and fascia with care using a soft cloth soaked with a neutral detergent. Regularly check

that the glass shield is not loose in the slots

Note: 

Ensure the lamps are cool enough to touch before handling. 

2. Lamp Replacement

1) Shut off the power before replacement.

2) Use ONLY Manrose 4W GU10 LED lamp for lighting - LHT0211

3) Use ONLY 1 000W halogen heat lamp for heating - LHT0326.

Note: 

Only use Manrose replacement bulbs as listed. Using other bulbs may damage the unit. 

WARRANTY - 5 YEARS/ HALOGEN LAMP - 1 YEAR 

The main unit and fan motor is warranted against factory fault for a period of 5 years and the original supplied 

MANROSE LED lamps for a period of 1 year. Labour costs are not covered. Please keep and bring the original invoice 

to your place of purchase for warranty services. For further warranty information, please see warranty card.

This warranty does not cover damage or loss caused by: 

1  LED lamp or failure of LED lamp. 

1  Halogen heat lamp or failure of halogen heat lamp. 

2  Any consequential losses arising from incorrect installation or operation or maintenance of this product. 

3  Any consequential losses arising from incorrect wiring of this product. 

4  Any consequential losses arising from repairing of any part of this product by unauthorised persons. 

MAIN TECHNICAL PARAMETERS 

LIST OF ACCESSORIES 

Model Number 

FAN5876 

Operation Unit 

Rated Voltage 

220V-240V AC 

1 000W Halogen Heat  Lamp (LHT0326) 

Rated Frequency 

50Hz 

Manrose 4W GU-10 LED Lamp (LHT0211) 

Rated Power 

990W-1080W 

Installation instruction & hole-cutting template 

Warranty card 

Ducting kit 

Backdraft stopper 

Duct Clip 

Switch 

Fill out the following details and file with the purchase invoice for warranty service. 

MODEL NO. FAN5876 

Purchased from: 

Date of purchase: ________________________ _ 

Note:  Instructions and specifications are subject to change without notice. 

1  piece 

1 piece 

4 pieces 

1 piece 
1 piece 

1 set 
1 set 

3 pieces 

1 piece 

Read and save these instructions! 

Please take this card as hole cutting template 470mm x 320mm. 

BY VENTAIR PTY LTD

CAPRI

PREMIUM HEAT, LIGHT AND EXHAUST

3 1

in

MANROSE Capri - Premium Heat, Light and Exhaust 3-in-1 Bathroom Unit.

Natural skin oils and salts damage new halogen lamps and 

shortern their life.

For the purpose of obtaining the best heating effect from the lamps they 
should be mounted between 2.2 and 2.7 metres from the ground.

Use this hole-cutting template to mark the hole on the ceiling. Make 
sure a distance between the edges of the unit and wall is no less than 
250mm. There should be a minimum 220mm vertical distance/space 
within the ceiling cavity.

Reviews: