C/
Swing bridge to the left as far as possible.
⇒
D/
Lower bridge.
⇒
E/
Bridge pins should enter pin hole on kettle
perfectly, If not return to step 1 and repeat leveling
steps.
⇒
F/
Raise bridge and swing to far right (for twin
mixers only).
⇒
G/
Repeat
steps
D
and
E
(for twin
mixers only).
7
.
Once
positioned
and leveled,
permanently
secure the
kettle's flanged feet to the floor using 5/16 inch
stainless steel lag bolts and floor anchors (supplied
by the installer). Secure each of the flanged feet with
one bolt in each hole. Seal joints of flanged feet with
a silicone sealant.
ELECTRICAL SERVICE
CONNECTIONS
ENSURE THE ELECTRICAL SUPPLY MATCHES THE
KETTLE'S REQUIREMENTS AS STATED ON THE
RATING LABEL.
Install in accordance with local codes and/or the National
Electric Code ANSI/NFPA No 70-1981 (USA) or the
Canadian Electric Code CSA Standard C22.1 (Canada). A
separate fused disconnect switch must be supplied and
installed. The kettle must be electrically grounded by the
installer.
The electric supply must match the power requirements
specified on the kettle's rating plate. The copper wiring
must be adequate to carry the required current at the rated
voltage.
1.
Ensure main power is turned off before connecting
wires.
2.
Remove the screws at the rear of the mixer console
cover, and remove the cover. A wiring diagram is
affixed to the underside of the console cover.
3.
Feed permanent copper wiring 18" through the cut-
out in the bottom of the console. Connect wiring in
junction box in the bottom of the console.
4.
Turn main power back on.
5.
Check for correct rotation of electric motor (access
by removing top front cover on center console). If
rotation is incorrect, disconnect main power and
reverse any two of the three live lines.
6.
Replace the console cover and secure it with
screws.
COMPRESSED AIR CONNECTION
Mixer Kettles with an air activated discharge valve require a
minimum of 90 PSI to operate correctly.
If the unit is also supplying air to a Metering Filling Station then
a pressure of 100 PSI at a minimum volume of 25 CFM is
required.
The air supplied to the mixer should be clean and dry. No oil
should be added to the supply air. We recommend the
compressed air system be equipped with a drier, filter, and
automatic water dump on the air compressor receiver tank. If
the distance between the tank and the unit is less than 100
feet then a minimum line size of 3/4" is required. A distance of
100 to 300 feet requires a minimum 1" line.
7/16"
Ø, 3 HOLES
ON
3 1/8"
(80mm) B.C.D.
FLANGED FOOT DETAIL
(REAR LEGS ONLY
)
120
120
4 7/8"
(124mm)