AIR LINE LUBRICATOR OIL
FILLING PROCEDURE
1.
Disconnect air supply and bleed system.
2.
Remove cover on console
3.
Check for oiler location.
4.
Inspect oil level in
bowl.
5.
Remove filler cap.
6.
Add mineral oil as
required.
7.
Replace filler cap
and console cover.
Oiler
Filler
Cap
Bowl
AIR FILTER REPLACEMENT
PROCEDURE
1.
Disconnect air supply and bleed system.
2.
Remove cover on console.
3.
Check for filter location.
4.
Push lever down
and rotate bowl/
guard assembly
1/8 turn.
5.
Push down on
bowl/guard
assembly
and remove.
6.
Unscrew baffle
and remove filter
element, inspect
and replace filter
if required.
7.
Replace filler cap
and cover.
Air Filter
Deflector
Filter
Element
Baffle
Lever
Bowl/Guard
Assembly
DISASSEMBLY OF SWITCH
ASSEMBLY
1.
Place slotted
screwdriver
between contactor
cartridge and
cartridge
mounting block as
shown in
Fig.1
.
2.
Twist screwdriver
to free cartridge.
3.
Place screwdriver
under tab in the
back of the
cartridge
mounting block as
shown in
Fig. 3
.
4.
Twist screwdriver
to remove block
from the rotary
switch.
3.
Unscrew locking
ring to remove
rotary switch.
Switch Assembly
Contactor
cartridges
Cartridge
mounting
block
Locking
ring
Rotary switch
Fig. 1
Fig. 3
Fig. 2
Fig. 4
HYDRAULIC OIL
REPLACEMENT PROCEDURE
One of the most important maintenance tasks is to
change the hydraulic oil yearly. Under heavy usage the
oil should be changed every nine months. It is important
to change the oil regularly to prevent its breakdown
which leads to the damaging of components.
The oil filter should be changed at the same time as
the hydraulic oil. A clean filter prevents particles from
damaging the other components in the system.
Replace the hydraulic fluid as follows:
⇒
Disconnect power to unit.
⇒
Remover the front top panel on the main console.
⇒
Remove chrome vent cap from breather pipe
located beside electric motor.
⇒
Remove plug bolt from bottom left front corner of
main console to drain oil into your catch pail.
⇒
Remove oil filter.
⇒
Replace plug bolt.
⇒
Refill unit through breather pipe using
approximately 12 U.S. gallons of Tellus 32
hydraulic oil (oil should be 6 1/2" deep in tank).
⇒
Install new oil filter (Part#
⇒
Replace chrome vent cap and front top panel.
⇒
Reconnect power to unit.
⇒
Run unit to remove any air in the lines.
NOTE:
Mixer may run rough and noisy for one or
two hours if air has become trapped in the line.