NOTE:
Use thread sealant compatible with propane gas
on all threaded piping connections.
1.
Disconnect electrical connection.
2.
Shut off main gas supply and disconnect kettle from
supply line.
3.
Remove main kettle
CONSOLE COVER
.
4.
Remove
PLUG
and
SPRING
.
5.
Remove
GAS ORIFICE
and
“O” RING
.
6.
Replace first with new
“O” RING
and then
GAS
ORIFICE
.
7.
Replace
SPRING
and
PLUG
.
8.
Replace main kettle
CONSOLE COVER
.
9.
Reconnect electrical supply.
Conversion Parts Required
KGL-40
Part No.
Description
Quantity
KE95591
Conversion Label
1
Air Intake Washer
1
Gas Orifice
1
“O” Ring
1
KGL-60 to 100
Part No.
Description
Quantity
KE95591
Conversion Label
1
Air Intake Washer
1
Gas Orifice
1
“O” Ring
1
FIELD CONVERSION
INSTRUCTIONS
Natural Gas to Propane Gas
CONSOLE COVER
NOTE:
Changing the gas type
requires a new Rating Label be affixed
to the unit.
When ordering conversion parts, it is
essential to provide both the Model #
and the Serial # of the unit in order to facilitate
completion of this label in the factory.
!
Kettles
BTU's per
Gas
Water
# of
Hour
Type
Column
Orifices
KGL-40,
140000
Natural Gas
3.5
1
KGL-40-T,
140000
Propane
3.5
1
KGL-60 to 100,
KGL-60-T to 80-T,
190000
Natural Gas
3.5
1
KGL-40-TSH,
190000
Propane
3.5
1
KGL-40-F to 60-F,
KGL-40-SH to 60-SH,
PLUG
SPRING
GAS ORIFICE
“O” RING