GAS KETTLE
ORIFICE REPLACEMENT
Gas Orifice
Console Cover
"O" Ring
Spring
Plug
1. Remove Console Cover
2. Remove Plug and Spring
3. Remove Orifice
4. Replace with new Orifice and "O" ring
5. Replace Spring and Plug
6. Replace Console Cover
Kettles
BTU's per
Gas
Water
# of
Hour
Type
Column
Orifices
KGL-40,
140000
Natural Gas
3.5
1
KGL-40-T,
140000
Propane
3.5
1
KGL-60 to 100,
KGL-60-T to 80-T,
190000
Natural Gas
3.5
1
KGL-40-TSH,
190000
Propane
3.5
1
KGL-40-F to 60-F,
KGL-40-SH to 60-SH,
NOTE:
Use thread sealant compatible with propane gas on
all threaded piping connections.
1.
Disconnect electrical connection.
2.
Shut off main gas supply and disconnect kettle from
supply line.
3.
Remove main kettle
CONSOLE COVER
.
4.
Remove
PLUG
and
SPRING
.
5.
Remove
GAS ORIFICE
and
“O” RING
.
6.
Replace first with new
“O” RING
and then
GAS
ORIFICE
.
7.
Replace
SPRING
and
PLUG
.
8.
Replace main kettle
CONSOLE COVER
.
9.