Table 5 Maximum Support Spacing and Footing Options in Wind Region B (Panels 2000x1100mm)
Wind Region
Regional Wind Speed (m/s)
Panels Tilt Angle
Max Spacing (m)
Footing Type
Continuous Paving Slab (LxT) (m)
Continuous Strip Footing (WxD) (m)
Individual Pad Footing per Leg (BxCxX) (m)
Transverse Strip Footing (LxAxD) (m)
B
48
Concrete Footing Options (min N25)
Front Leg
0.35x0.45
2.50x0.75x0.70
2.85x0.85x0.80
0.55x0.65
0.45x0.45
0.65x0.65
0.55x0.55x0.75
0.95x0.95x0.90
0.75x0.75x0.75
1.05x1.05x0.90
2.30x0.20
2.40x0.25
Rear Leg
Front Leg
Rear Leg
20°
3.50
30°
2.95
Table 6 Maximum Support Spacing and Footing Options in Wind Regions C & D (Panels 2000x1100mm)
Note(*)
:
when using east west adaptor
Wind Region
Regional Wind Speed (m/s)
Panels Tilt Angle
Max Spacing (m)
Footing Type
Continuous Paving Slab (LxT) (m)
Continuous Strip Footing (WxD) (m)
Individual Pad Footing per Leg (BxCxX) (m)
Transverse Strip Footing (LxAxD) (m)
Concrete Footing Options (min N25)
Front Leg
0.50x0.55
2.70x0.85x0.80
2.90x0.80x0.80
0.55x0.60
0.55x0.55
0.70x0.60
0.60x0.60x0.75
0.70x0.70x0.75
0.75x0.75x0.75
0.80x0.80x0.75
2.40x0.25
2.65x0.30
Rear Leg
Front Leg
Rear Leg
C
59
20°
3.00
D
73
20°
2.00(1.90*)