SUPERVISOR CONTROLS
Tennant T300 (02- 2016)
53
ATTENTION:
The following instructions are intended
for supervisor use only. Remove pages from manual if
necessary.
SUPERVISOR CONTROLS
The supervisor controls feature allows a supervisor to
program the machine’s scrubbing settings for operator
use. The lockout functionality will prevent the operator
from changing or saving the Zone Settings.
The supervisor controls feature will lower machine
variability for consistent, repeatable cleaning results,
machine quality assurance regardless of user
experience, and reduce user training requirements.
T300 MODEL WITH PRO-MEMBRANE CONTROL
PANEL
The machine has three supervisor control modes of
operation to choose from:
Unlocked Mode 1:
Operator has full control of all
scrubbing parameters with the ability to save Zone
Settings. The Unlocked Mode 1 is the factory default
setting.
Lockout Mode 2:
Zone Settings are configured and
locked by supervisor. Operator has control to
reconfigure the zone settings, but are not able to save
them.
Lockout Mode 3
: Zone Settings are configured and
locked by supervisor. Operator is restricted to only use
the Zone Settings configured by supervisor.
To enter the supervisor controls mode follow the
instructions below:
1. Park the machine on a level surface and turn the
key to off ( O ) position.
2. Press and hold the Down Pressure button while
turning the key on. Release button when the far
right battery discharge indicator LED turns on
(Figure 133).
FIG. 133
3. Select the preferred supervisor control mode by
pressing the following Zone Setting buttons as
described:
Zone 1 button = Unlocked mode 1
Zone 2 button = Lockout mode 2
Zone 3 button = Lockout mode 3
Hold down the Zone Setting button until it blinks
three times to save the preferred supervisor control
mode (Figure 134). In this example, Lockout mode
3 was selected.
FIG. 134
4. If Lockout mode 2 or 3 was selected, press the
Solution Flow button. This will allow you to
configure the Zone Settings for the selected
supervisor control mode (Figure 135).
FIG. 135
5. Configure the following Zone Settings for zone 1.
After the Zone Settings are configured, press and
hold the zone button until it blinks three times to
save Zone Setting. Repeat process for other
zones.
Zone Settings:
- Down pressure rate
- Solution flow rate
- Quiet-Mode on or off (option)
- ec-H2O mode on or off (option)
- Maximum scrubbing speed (drive model)
To adjust the maximum scrub speed, press the
circled button to cycle through the five speed
selections as described below (Figure 136).
The speed selection is displayed by the battery
discharge indicator LED’s. The red LED represents
the lowest speed. The far right green LED
represents the highest speed (Figure 136).
Low
High
Speed Selection
Hidden Button
Severe Env. Button
FIG. 136
6. To exit the supervisor control mode, turn key off.