background image

OPERATION

26

Tennant T300 (02- 2017)

HOUR METER

The hour meter records the number of hours the

machine has been operated. Use the hour meter to

perform specific maintenance procedures and to record

service history (Figure 75).

FIG. 75

DRAINING TANKS

FOR SAFETY: Before leaving or servicing machine,

stop on level surface, turn off machine, remove key

and set parking brake if equipped.

DRAINING RECOVERY TANK

Drain and clean the recovery tank daily and between

solution tank refills.
1. Transport the machine to drain area.
2. For models equipped with drain hose caps, hold

the hose upward, remove cap then slowly lower

hose to drain. For models equipped with flow

control valve drain hose, lower hose and slowly

open valve to drain (Figure 76).

FIG. 76

NOTE:

When using a bucket to drain the machine, do

not use the same bucket to fill the solution tank.

3. Remove and clean the float shut-off screen

(Figure 77).

FIG. 77

4. Remove the debris tray and empty (Figure 78).

FIG. 78

5. Rinse out the recovery tank with clean water and

wipe clean of any soil residue (Figure 79).

FIG. 79

Summary of Contents for Tennant GL20

Page 1: ...T300 SCRUBBER DRYER OPERATOR MANUAL Clemas Co Unit 5 Ashchurch Business Centre Alexandra Way Tewkesbury Gloucestershire GL20 8NB Tel 01684 850777 Fax 01684 850707 Email info clemas co uk Web www clema...

Page 2: ...ain portions of software that have various 3rd party licenses More information can be found at www tennantco com opensource Specifications and parts are subject to change without notice Original Instr...

Page 3: ...TION CHECK LIST 23 OPERATING MACHINE 23 WHILE OPERATING MACHINE 24 EMERGENCY SHUT OFF BUTTON Drive models 25 BATTERY DISCHARGE INDICATOR 25 CIRCUIT BREAKER PANEL 25 HOUR METER 26 DRAINING TANKS 26 DRA...

Page 4: ...d Magnetic pad driver brush can be harmful to pacemaker wearers or medical implants WARNING This machine contains chemicals known to the state of California to cause cancer birth defects or other repr...

Page 5: ...ed during charging cycle disconnect the AC power supply cord first Do not use incompatible battery chargers as this may damage battery packs and potentially cause a fire hazard Inspect charger cord re...

Page 6: ...ydrogen gas Explosion or fire can result Keep sparks and open flame away when charging Located on bottom side of recovery tank WARNING LABEL Spinning pad Keep hands away Located on disk scrub head mod...

Page 7: ...Accessory rail 9 On board battery charger cord hooks 10 Scrub head lift pedal 11 Squeegee foot pad 12 Squeegee assembly 13 Control handle 14 Control handle start bail 15 Speed control knob drive model...

Page 8: ...e lever near left rear wheel 3 Battery discharge indicator BDI The battery discharge indicator serves two functions In normal scrub mode it displays the charge level of the batteries It also in conjun...

Page 9: ...or quick operation The factory zone settings are configured with different solution flow rates down pressures and maximum scrub speeds T300 Model with Pro Panel Controls LCD Liquid Crystal Display 10...

Page 10: ...run time See BATTERY CHARGER SETTINGS IRIS Battery Charging Metrics Notification Machines equipped with capability to report battery charging data via IRIS are supplied with a charger and set of batt...

Page 11: ...is best suited NOTE The amount and type of soilage play an important role in determining the type of brush or pad to use Contact a Tennant representative for specific recommendations Soft nylon brist...

Page 12: ...Disk FOR SAFETY Before leaving or servicing machine stop on level surface turn off machine remove key and set parking brake if equipped WARNING Magnetic Field Hazard Magnetic pad driver brush can be h...

Page 13: ...machine stop on level surface turn off machine remove key and set parking brake if equipped 1 Step down on the scrub head lift pedal to raise the scrub head off the floor Figure 13 FIG 13 2 Install th...

Page 14: ...k with only cool clean water less than 70 F 21 C Do not add conventional floor cleaning detergents An ec H2O system fault will occur if cleaning detergents are added Conventional Scrubbing Fill soluti...

Page 15: ...en refilling the solution tank 3 Adjust the mixing ratio knob according to the cleaning detergent s mixing instructions Figure 25 FIG 25 ec H2O NanoClean WATER CONDITIONING CARTRIDGE ec H2O model The...

Page 16: ...with the optional accessory clips the clips easily clip on and off the rail for additional accessory storage Figure 29 FIG 29 To install the accessory clips hook the clip over the rail and push downwa...

Page 17: ...ense press and hold the button for 2 seconds until LED turns solid green Press button at anytime to turn off The icon will blink blue when the severe environment tank needs to be refilled NOTE When th...

Page 18: ...No LED No flow One LED Low flow two LED s Medium flow three LED s High flow FIG 39 4 Models equipped with Severe Environment button option Press Severe Environment button one time to dispense cleanin...

Page 19: ...Replace cartridge Solid or blinking red See Service Indicator Codes T300 MODEL WITH PRO PANEL CONTROLS There are two types of user modes that will interface with the operator home screen Operator Mod...

Page 20: ...ase down pressure Press the symbol to decrease the down pressure FIG 48 4 Press the solution flow icon to display the solution flow scale Figure 49 Press the symbol to increase solution flow Press the...

Page 21: ...with different solution flow rates down pressures and maximum scrub speeds FIG 53 To change the default zone settings Configure the desired zone settings then press and hold the zone number button un...

Page 22: ...at back of manual 10 The service indicator icon on the home screen will flash yellow or red when a machine fault is detected Figure 59 FIG 59 In conjunction with a flashing service indicator icon the...

Page 23: ...osition Figure 63 FIG 63 3 ec H2O models The ec H2O system will automatically turn on at start up To turn off the ec H2O system press the ec H2O switch located below the key switch ATTENTION During fi...

Page 24: ...blades leave streaks 4 Avoid bumping the machine into posts and walls 5 When draining and refilling machine always top off the optional Severe Environment tank with detergent FOR SAFETY When operatin...

Page 25: ...en the red light is flashing this will allow user to transport machine to charging station T300 T300 LCD FIG 72 CIRCUIT BREAKER PANEL The machine is equipped with resettable circuit breakers to protec...

Page 26: ...very tank daily and between solution tank refills 1 Transport the machine to drain area 2 For models equipped with drain hose caps hold the hose upward remove cap then slowly lower hose to drain For m...

Page 27: ...if equipped 2 To drain remaining water from solution tank pull the solution hose from the accessory rail Figure 80 FIG 80 Firmly reconnect the solution hose to accessory rail after draining tank 3 Ri...

Page 28: ...ontact service S S S 0x0301 Solution valve wiring connec tor or control board problem Check connections Contact service S S 0x0303 Solution valve over current Contact service S S 0x0307 Solution valve...

Page 29: ...ronment detergent pump over current Contact service S S 0x0606 Severe environment detergent pump shorted fault Contact service S 0x0106 Brush motor shorted fault Contact service S S 0xF103 0xFF20 0x07...

Page 30: ...pump breaker tripped Reset circuit breaker If trip repeats contact service ecH2O indicator solid red 0x0716 0x0717 0x0727 0x0741 0x0746 0x0747 ec H2O pump shorted fault ec H2O pump control board fault...

Page 31: ...b head skirt Check for damage and wear Weekly O 7 Battery cells Check electrolyte level O 6 Squeegee assembly drip trap reservoir Check clean 50 Hours O 2 Cylindrical brushes Rotate brushes Check for...

Page 32: ...All repairs must be performed by trained personnel AFTER DAILY USE 1 Drain and rinse out the recovery tank Figure 83 See DRAINING TANKS FIG 83 2 Remove the debris tray and empty Figure 84 FIG 84 3 Rem...

Page 33: ...ll purpose cleaner and damp cloth Figure 92 FIG 92 10 Cylindrical scrub head Remove and clean debris trough Figure 93 FIG 93 11 Severe environment option Refill the severe environment tank with a reco...

Page 34: ...and clean the seal on the recovery tank lid Figure 101 Replace seal if damaged FIG 101 AFTER EVERY 100 HOURS OF USE If machine is equipped with the optional battery watering system check the watering...

Page 35: ...long period of time S Only charge the batteries in a well ventilated area to prevent gas build up Charge batteries in areas with ambient temperatures 80_F 27_C or less S Allow the charger to complete...

Page 36: ...not equipped with charger FOR SAFETY The use of incompatible battery chargers may damage battery packs and potentially cause a fire hazard IMPORTANT NOTICE The battery charger is set to charge the ba...

Page 37: ...ou choose to change to a different battery type or capacity the charger s charging profile must be changed to prevent battery damage The machine s battery discharge indicator BDI must also be reprogra...

Page 38: ...NOTE The manual method is only an alternative if unable to change setting by use of the Service Application Software performed by Service 1 Disconnect battery cables Figure 111 FIG 111 2 Unwrap the b...

Page 39: ...board battery charger settings for a different battery type 1 Turn the key to the on position 2 Press the settings button located on the home screen Figure 116 FIG 116 3 Press the Setup button to acce...

Page 40: ...m Figure 122 The level indicators will turn black when full FIG 122 6 After adding water replace the dust cap on the battery fill hose and store the hand pump hose inside the machine s battery compart...

Page 41: ...de when it s time to replace cartridge See CONTROL PANEL OPERATION for further details Depending on machine usage on average a new cartridge can last anywhere from 12 months for heavy machine usage to...

Page 42: ...nsporting the machine by use of trailer or truck carefully follow the loading and tie down procedure 1 Raise the scrub head and remove squeegee assembly 2 Use a ramp that can support the machine weigh...

Page 43: ...filter located under machine Replace filter 3 Pour 1 gallon 4 liters of propylene glycol based recreational vehicle RV antifreeze into the solution tank Models equipped with optional Severe Environme...

Page 44: ...lace batteries Battery charger fault detected See SERVICE INDICATOR CODES Faulty charger Replace charger Machine will not propel Drive Model Propel fault has been detected See SERVICE INDICATOR CODES...

Page 45: ...en Recovery tank lid not completely closed Check lid for obstructions Defective seals on recovery tank lid Replaced seal Little or no solution flow Empty solution tank Refill solution tank Low solutio...

Page 46: ...208ft2 hr 1041m2 hr 12 453ft2 hr 1157m2 hr 14 943ft2 hr 1388m2 hr ec H2O productivity rate est actual 9 668 ft2 hr 898 m2 hr 11 602ft2 hr 1078m2 hr 12 891ft2 hr 1198m2 hr 15 469ft2 hr 1437m2 hr Aisle...

Page 47: ...5 in 1346 mm 52 in 1321 mm 49 in 1245 mm Ramp incline for scrubbing 9 max Ramp incline for transporting 21 max Ramp incline for loading empty tanks 21 max Solution flow rate Low 15 gpm 57 L min Med 35...

Page 48: ...Tennant T300 03 2015 MACHINE DIMENSIONS 43 1 in 1095 mm 30 4 in 772 mm SINGLE DISK MODEL 51 25 in 1302 mm 17 in 43 cm Model 54 in 1372 mm 20 in 50 cm Model 20 in 508 mm 17 in 43 cm Model 22 in 559 mm...

Page 49: ...SPECIFICATIONS Tennant T300 03 2015 49 43 1 in 1095 mm 30 4 in 772 mm DUAL DISK MODEL 51 25 in 1314 mm 26 in 660 mm...

Page 50: ...SPECIFICATIONS 50 Tennant T300 03 2015 43 1 in 1095 mm 30 4 in 772 mm CYLINDRICAL BRUSH MODEL 50 5 in 1283 mm 25 in 635 mm...

Page 51: ...SPECIFICATIONS Tennant T300 03 2015 51 43 1 in 1095 mm 30 4 in 772 mm ORBITAL PAD MODEL 49 in 1245 mm 20 5 in 521 mm...

Page 52: ...SPECIFICATIONS 52 Tennant T300 03 2015...

Page 53: ...O position 2 Press and hold the Down Pressure button while turning the key on Release button when the far right battery discharge indicator LED turns on Figure 133 FIG 133 3 Select the preferred supe...

Page 54: ...start up Figure 137 This is the factory default screen at start up NOTE If a login screen appears at start up Enter the factory assigned supervisor login number or your saved personalized supervisor l...

Page 55: ...le list FIG 142 4 Enter the new user s profile ID identification then press the green forward arrow Figure 143 FIG 143 5 Create an assigned login number for the new user profile then press the green a...

Page 56: ...Settings button then pressing the logout button Figure 149 Turning the key to the off position is another way to also logout FIG 149 11 Use the edit copy and delete profile buttons to manage the curr...

Page 57: ...Press the yes button to enter the Default User screen Figure 154 FIG 154 c Select the desired default user by pressing the Operator or Supervisor button Figure 155 FIG 155 d Select a pre assigned use...