MAINTENANCE
Tennant T300 (02- 2017)
39
* The CAN-BUS setting, dial position “0”, is the
software setting that is programmed to match battery
type supplied with machine. When the dial is manually
changed to a different setting, it should not be reset
back to “0” otherwise battery damage may result.
Service Application Software is required to reset dial
back to “0”. Contact Service.
7. Replace the black cap on charger, reinstall battery
charger and replace control console.
8. Reconnect the battery cable connection.
9. To set the BDI for the new battery type, plug the
on- board battery charger cord into an electrical
outlet. The machine’s software will automatically
reprogram the BDI to the new battery type.
CHANGING ON-BOARD BATTERY CHARGER
SETTINGS (Pro-Panel model)
NOTE: To perform this procedure, machine must be in
supervisor mode.
See SUPERVISOR CONTROLS
instructions at back of manual.
To change the on-board battery charger settings for a
different battery type :
1. Turn the key to the on position.
2.
Press the settings button located on the
home screen (Figure 116).
FIG. 116
3.
Press the Setup button to access the Setup
screen (Figure 117).
FIG. 117
4.
Press the Battery Type button to select the
battery type installed in machine (Figure 118).
FIG. 118
HYDROLINK
BATTERY WATERING SYSTEM
(Trojan 150AH Battery Option)
The following instructions are for models equipped with
the HydroLINK battery watering system option.
The optional HydroLINK battery watering system
provides a safe and easy way to maintain the proper
electrolyte levels in your batteries. It is designed
exclusively for Trojan
flooded (wet) lead-acid
batteries.
FOR SAFETY: When servicing machine, wear
personal protection equipment as needed. Avoid
contact with battery acid.
Before using the battery watering system check hoses
and connections for damage or wear.
1. Fully charge batteries prior to using the battery
watering system. Do not add water to batteries
before charging, the electrolyte level will expand
and may overflow when charging.