SM-P00077-A/3
4. MAINTENANCE AND INSPECTION
76
2020-04-15
4.3.4
Instructions for wiring the electric circuit board connectors
Rules for establishing correspondence between the connectors on the electric circuit board and the
valves differ depending on the wiring specifications. When wiring the electric circuit board connectors,
always check the connector numbers printed on the circuit board.
The connector number in the table (Connector no.) indicates the pin number for each connector.
Wire in the order indicated by the arrows.
Electric circuit board assembly
Correspondence between connectors and valves
T10
1) Single solenoid valves only (maximum of 16 stations)
Connector no.
16
15
14
13
12
11
10
9
Valve no.
16a
15a
14a
13a
12a
11a
10a
9a
Connector no.
8
7
6
5
4
3
2
1
Valve no.
8a
7a
6a
5a
4a
3a
2a
1a
2) Double solenoid valves only (maximum of 8 stations)
Connector no.
16
15
14
13
12
11
10
9
Valve no.
8b
8a
7b
7a
6b
6a
5b
5a
Connector no.
8
7
6
5
4
3
2
1
Valve no.
4b
4a
3b
3a
2b
2a
1b
1a
3) Mixed (both single and double) (maximum of 16 solenoids)
Connector no.
16
15
14
13
12
11
10
9
Valve no.
Empty Empty Empty Empty Empty Empty
7b
7a
Connector no.
8
7
6
5
4
3
2
1
Valve no.
6a
5b
5a
4b
4a
3a
2a
1a
T11
1) Single solenoid valves only (maximum of 20 stations)
Connector no.
24
23
22
21
20
19
18
17
16
15
14
13
Valve no.
Empty Empty Empty Empty
20a
19a
18a
17a
16a
15a
14a
13a
Connector no.
12
11
10
9
8
7
6
5
4
3
2
1
Valve no.
12a
11a
10a
9a
8a
7a
6a
5a
4a
3a
2a
1a
2) Double solenoid valves only (maximum of 12 stations)
Connector no.
24
23
22
21
20
19
18
17
16
15
14
13
Valve no.
12b
12a
11b
11a
10b
10a
9b
9a
8b
8a
7b
7a
Connector no.
12
11
10
9
8
7
6
5
4
3
2
1
Valve no.
6b
6a
5b
5a
4b
4a
3b
3a
2b
2a
1b
1a
3) Mixed (both single and double) (maximum of 24 solenoids)
Connector no.
24
23
22
21
20
19
18
17
16
15
14
13
Valve no.
Empty Empty Empty Empty Empty Empty Empty Empty Empty Empty Empty Empty
Connector no.
12
11
10
9
8
7
6
5
4
3
2
1
Valve no.
Empty Empty
7b
7a
6a
5b
5a
4b
4a
3a
2a
1a
T30
1) Single solenoid valves only (maximum of 20 stations)
Connector no.
1
2
3
4
5
6
7
8
9
10
11
12
Valve no.
1a
3a
5a
7a
9a
11a
13a
15a
17a
19a
Empty Empty
Connector no.
14
15
16
17
18
19
20
21
22
23
24
25
Valve no.
2a
4a
6a
8a
10a
12a
14a
16a
18a
20a
Empty Empty
2) Double solenoid valves only (maximum of 12 stations)
Connector no.
1
2
3
4
5
6
7
8
9
10
11
12
Valve no.
1a
2a
3a
4a
5a
6a
7a
8a
9a
10a
11a
12a
Connector no.
14
15
16
17
18
19
20
21
22
23
24
25
Valve no.
1b
2b
3b
4b
5b
6b
7b
8b
9b
10b
11b
12b
3) Mixed (both single and double) (maximum of 24 solenoids)
Connector no.
1
2
3
4
5
6
7
8
9
10
11
12
Valve no.
1a
3a
4b
5b
7a
Empty Empty Empty Empty Empty Empty Empty
Connector no.
14
15
16
17
18
19
20
21
22
23
24
25
Valve no.
2a
4a
5a
6a
7b
Empty Empty Empty Empty Empty Empty Empty