SM-P00077-A/3
4. MAINTENANCE AND INSPECTION
77
2020-04-15
Wire in the order indicated by the arrows.
Electric circuit board assembly
Correspondence between connectors and valves
T50
T6*
1) Single solenoid valves only (maximum of 16 stations)
Connector no.
1
2
3
4
5
6
7
8
Valve no.
1a
2a
3a
4a
5a
6a
7a
8a
Connector no.
11
12
13
14
15
16
17
18
Valve no.
9a
10a
11a
12a
13a
14a
15a
16a
2) Double solenoid valves only (maximum of 8 stations)
Connector no.
1
2
3
4
5
6
7
8
Valve no.
1a
1b
2a
2b
3a
3b
4a
4b
Connector no.
11
12
13
14
15
16
17
18
Valve no.
5a
5b
6a
6b
7a
7b
8a
8b
3) Mixed (both single and double) (maximum of 16 solenoids)
Connector no.
1
2
3
4
5
6
7
8
Valve no.
1a
2a
3a
4a
4b
5a
5b
6a
Connector no.
11
12
13
14
15
16
17
18
Valve no.
7a
8a
8b
Empty
Empty
Empty
Empty
Empty
T51
1) Single solenoid valves only (maximum of 18 stations)
Connector no.
17
15
13
11
9
7
5
3
1
Valve no.
17a
15a
13a
11a
9a
7a
5a
3a
1a
Connector no.
18
16
14
12
10
8
6
4
2
Valve no.
18a
16a
14a
12a
10a
8a
6a
4a
2a
2) Double solenoid valves only (maximum of 9 stations)
Connector no.
17
15
13
11
9
7
5
3
1
Valve no.
9a
8a
7a
6a
5a
4a
3a
2a
1a
Connector no.
18
16
14
12
10
8
6
4
2
Valve no.
9b
8b
7b
6b
5b
4b
3b
2b
1b
3) Mixed (both single and double) (maximum of 18 solenoids)
Connector no.
17
15
13
11
9
7
5
3
1
Valve no.
Empty
Empty
Empty
8b
7a
5b
4b
3a
1a
Connector no.
18
16
14
12
10
8
6
4
2
Valve no.
Empty
Empty
Empty
Empty
8a
6a
5a
4a
2a
T52
1) Single solenoid valves only (maximum of 8 stations)
Pin no.
7
5
3
1
Valve no.
7a
5a
3a
1a
Pin no.
8
6
4
2
Valve no.
8a
6a
4a
2a
2) Double solenoid valves only (maximum of 4 stations)
Connector no.
7
5
3
1
Valve no.
4a
3a
2a
1a
Connector no.
8
6
4
2
Valve no.
4b
3b
2b
1b
3) Mixed (both single and double) (maximum of 8 solenoids)
Connector no.
7
5
3
1
Valve no.
5b
4b
3a
1a
Connector no.
8
6
4
2
Valve no.
6a
5a
4a
2a