SM-P00077-A/3
2. INSTALLATION
34
2020-04-15
2.3.3
How to mount a manifold
◼
Mounting with DIN rail
The manifold can be mounted on the DIN rail by selecting a DIN rail mount manifold (mount type symbol:
D) or by modifying a direct mount manifold with the DIN rail kit. If not mounted correctly, the manifold
may fall off or become damaged. If the installation environment is subject to vibrations or shocks, secure
the DIN rail onto the mounting surface at intervals of 50 mm to 100 mm and make sure that there is no
abnormality with the mounting condition.
M4G1 R Series
M4G2 R, M4G3 R Series
Lock nut
Mounting screw
Make sure to tighten the lock nuts.
Be careful not to apply excessive
tightening torque, as this may deform
the DIN rail.
DIN rail
Tightening torque: 0.3 N·m
to 0.5 N·m
1. Attach the holder. (Secure with tapping screws
to prevent it from falling off.)
2. Temporarily fasten the mounting screws.
3. Hook the manifold to DIN rail in order from
(1) to (2).
4. Push in the direction of (3).
5. Tighten the mounting screws.
Holder
Tapping screw
DIN rail
(1)
(2)
(3)
Mounting screw
Tightening torque: 0.7 N·m to 1.0 N·m