SM-P00077-A/3
1. PRODUCT OVERVIEW
21
2020-04-15
1.3.3
Response times
(Unit: ms)
Solenoid position
4GA/B R Series
4GD/E R Series
4GA/B1 R
4GA/B2 R
4GA/B3 R
4GD/E1 R
4GD/E2 R
4GD/E3 R
ON
OFF
ON
OFF
ON
OFF
ON
OFF
ON
OFF
ON
OFF
Two 3-port valves
integrated type
9
12
12
29
-
-
12
15
15
30
-
-
2-position
Single
12
12
19
19
25
28
15
25
20
30
25
40
Double
9
-
18
-
24
-
15
-
20
-
25
-
3-position
ABR
connection
8
15
17
30
23
45
20
30
25
35
35
50
* Values determined with surge suppressor/lamp are shown. They are values determined with a supply pressure of 0.5 MPa, a
temperature of 20°C, and no lubrication. Response times vary depending on pressure and quality of lubricant.
1.3.4
Flow characteristics
◼
Single valve
Model
Solenoid position
1(P) -> 4(A)/2(B)
4(A)/2(B) -> 5(R1)/3(R2)
C [dm
3
/(s/bar)]
b
C [dm
3
/(s/bar)]
b
3GA1 R
4GA1 R
3GD1 R
4GD1 R
Two 3-port valves integrated type
0.98
0.45
0.71
0.34
2-position
1.2
0.47
0.72
0.37
3-position
All ports closed
1.1
0.39
0.70
0.34
ABR connection
1.1
0.33
0.72
0.34
PAB connection
1.3
0.61
0.72
0.36
3GA2 R
4GA2 R
3GD2 R
4GD2 R
Two 3-port valves integrated type
1.8
0.29
2.3
0.32
2-position
2.4
0.33
2.8
0.30
3-position
All ports closed
2.2
0.28
2.5
0.28
ABR connection
2.3
0.26
2.8
0.27
PAB connection
2.5
0.38
2.4
0.30
3GA3 R
4GA3 R
3GD3 R
4GD3 R
2-position
3.4
0.29
4.0
0.24
3-position
All ports closed
3.1
0.27
3.4
0.28
ABR connection
3.1
0.33
4.1
0.20
PAB connection
3.5
0.43
3.4
0.32
3GB1 R
4GB1 R
3GE1 R
4GE1 R
Two 3-port valves integrated type
0.92
0.08
1.1
0.26
2-position
1.3
0.27
1.2
0.22
3-position
All ports closed
1.1
0.31
1.1
0.27
ABR connection
1.1
0.31
1.3
0.29
PAB connection
1.4
0.30
1.1
0.26
3GB2 R
4GB2 R
3GE2 R
4GE2 R
Two 3-port valves integrated type
1.7
0.42
2.1
0.26
2-position
2.6
0.20
2.6
0.19
3-position
All ports closed
2.3
0.32
2.2
0.22
ABR connection
2.2
0.23
2.6
0.16
PAB connection
2.4
0.10
2.4
0.22
4GB3 R
4GE3 R
2-position
4.3
0.24
4.2
0.24
3-position
All ports closed
3.3
0.40
3.4
0.27
ABR connection
3.3
0.36
4.2
0.18
PAB connection
4.5
0.28
3.4
0.30
* C: Sonic conductance, b: Critical pressure ratio