SM-P00077-A/3
2. INSTALLATION
41
2020-04-15
2.5.1
E-type connector
E-type connector has entries on both the top and side to which a socket can be connected from either
direction. The socket is attached to the side entry at shipment. Change the connecting direction
depending on the installation environment.
◼
Attaching and detaching the socket
To attach the socket, hold the lever and the
socket body with your fingers and insert the
socket straight into the entry on the connector
body.
Hook the tab on the lever into the slot on the
connector body to lock the socket in place. To
attach to the top entry, position the socket so that
the lever is in front. To attach to the side entry,
position the socket so that the lever is on top.
To detach the socket, depress the lever to release
the tab from the slot, and pull it out straight.
◼
Connecting the lead wires
Strip the end of the lead wires by approximately 3
mm. Align the end of conductors, insert them into
the contact terminal, and crimp with a crimp tool.
When crimping, make sure that both the sheath
and the conductors are held and 0 mm to 0.5 mm
of the conductor end is visible.
After crimping, position the contact terminal as
shown in the figure to the right and insert it into
the entry on the socket.
Insert the terminal until it hits the end to lock it in
place. Pull gently on the terminal to check that it
is locked.
2.5.2
A-type connector
A-type connector is a connector exclusively designed for reduced wiring manifold, with which wires can
be connected from the bottom. When attaching or detaching the socket, observe the same instructions
as the E-type connector.
Lever
Socket
Slot
Entry (top)
Entry (side)
Sheath and wire
are held
Wire size
0.08 mm
2
to 0.16 mm
2
AWG26 to 28
Conductors
are visible
0 mm to 0.5 mm
View A