2 to 1 Configuration
RVP_Direct
The EXTender Remote Unit communicates with the Gateway installed at the corporate facility. The
Gateway can connect to two different EXTender remote units using RVP_Direct to both WAN Ports. The
first remote is connected to WAN1 of the Gateway and the second remote is connected to WAN2 of the
Gateway. Once you configure the Gateway to accommodate two separate remote units, you must
configure the following EXTender parameters:
Remote Number:
This number (1 or 2) identifies the Gateway WAN port connected to the EXTender.
Gateway Port Offset:
This parameter is used to allow the lower port numbers on Remote 2 access to the
Gateway unit.
Example
: If the Gateway port offset is set to 8, when port 1 on the Remote connects, it connects to port 9
on the Gateway.
Procedure
1. Access the Connect menu using the following path:
Path:
Remote->Configuration->Connect
The following menu appears:
Figure 15: Gateway Port Offset
2. Press
the
Æ
key, then the
È
key to access the
Gateway Port Offset
parameter. Enter a digit (1-8) to
set the value and press
Enter
. Entering 0 would mean there is no port offset value, or there is no 2:1
configuration.
3. Press
the
Ç
and
Æ
keys to access the RVP_Direct menu.
EXTender™ IP6000 Quick Installation Guide