45
xStatus SystemUnit Software MaxVideoCalls
Shows the maximum number of simultaneous video calls that is supported by the software
installed. May vary depening of the selected network interface type and other configuration.
Format:
Integer.
xStatus SystemUnit Software MaxAudioCalls
Shows the maximum number of simultaneous audio calls that is supported by the software
installed.
Format:
Integer.
xStatus SystemUnit Hardware Module SerialNumber
Shows the serial number of the system.
Format:
String.
xStatus SystemUnit Hardware Module Identifier
Shows the revision of the system.
Format:
String.
xStatus SystemUnit Hardware MainBoard SerialNumber
Shows the serial number of the main board in the system.
Format:
String.
xStatus SystemUnit Hardware MainBoard Identifier
Shows the revision of the main board in the system.
Format:
String.
xStatus SystemUnit Hardware MainBoard CPLDFirmware
Shows the version of installed CPLD firmware.
Format:
String.
xStatus SystemUnit Hardware MainBoard Temperature
Shows the temperature (in degrees Celsius) of the system's main board.
Format:
String.
xStatus SystemUnit State Status
Shows the system state, i.e. whether there are any errors or warnings issued.
Initializing:
the system is initializing and not yet ready for use.
OK:
the system is ready for use.
OKWithWarning:
the system can be used for making calls, but there are warnings issued
that might influence its behavior.
Error:
the system is in an erroneous state and cannot be used for making calls.
xStatus SystemUnit State StatusCode
Shows the type of error or warning that is issued for the system (if any).
OK:
the system is ready for use.
EthLinkDown:
there is no ethernet connection, and thus the ISDN Link cannot be used.
BRIWarning:
A warning is issud for the BRI interface.
BRIError:
there is an error on the BRI interface.
PRIError:
there is an error on the PRI interface.
ExtNetError:
there is an error on the external network interface (Net).
Initializing:
the system is initializing and not yet ready for use.
xStatus SystemUnit State StatusText
textual description of the system state, e.g. type of alarm if in an erroneous state.
Format:
String.
Contents
Introduction
Getting started
Software upgrade
Status information
System settings
Appendices
Status information