ISDN PRI ChanId
Select if PRI Channel ID information should be sent to the PXB.
Value space:
<Off/On>
Off:
When set to off, Channel ID information is not sent. Default setting is off.
On:
When set to on, the system will signal to the PBX which PRI channels is used for the call.
Note: this setting must be set to on, to work with an ericsson MD110 PBX.
ISDN PRI InitialRestart
Select if the system should re-initialize the PRI interfaces after the system has been restarted.
Value space:
<Off/On>
Off:
When set to off, the PRI interface will not be re-initialized after restart.
On:
When set to on, the PRI interfaces will be re-initialized after restart of the system.
ISDN PRI L2WindowSize
Set Layer 2 window size (ISDN Layer 2).
Value space:
<1..7>
Range:
Select a value between 1 and 7.
ISDN PRI SwitchType
Selects the type of PRI switch the system is connected to.
Value space:
<NI/ATT/Euro/Japan>
NI:
Select NI if the switch is a National ISDN switch type.
ATT:
Select Att if the switch is an At&t (for the u.S.) ISDN switch type.
Euro:
Select euro if the switch is an euro (uK and others) ISDN switch type.
Japan:
Select Japan if the switch is a Japanese ISDN switch type.
ISDN PRI Interface [1..1] HighChannel
Set the highest numbered B-channel that may be used by the system when selecting channels
for outgoing calls.
Value space:
<1..31>
Range:
Select a value between 1 and 31.
ISDN PRI Interface [1..1] LowChannel
Set the lowest numbered B-channel that may be used by the system when selecting channels
for outgoing calls.
Value space:
<1..31>
Range:
Select a value between 1 and 31.
ISDN PRI Interface [1..1] MaxChannels
Set the maximum number of channels the system may use at any given time.
Value space:
<1..30>
Range:
Select a value between 1 and 30.
ISDN PRI Interface [1..1] NumberRangeStart
If the PRI line has a range of numbers, the first number in the range should be entered in the
Number Range Start field.
Value space:
<S: 0, 24>
Format:
String with a maximum of 24 characters.
ISDN PRI Interface [1..1] NumberRangeStop
If the PRI line has a range of numbers, the last number in the range is entered in the Number
Range Stop field.
Value space:
<S: 0, 24>
Format:
String with a maximum of 24 characters.