Cisco SCE 2000 and SCE 1000 Software Configuration Guide
OL-7827-12
Chapter 4 Utilities
The Setup Command
Information regarding these parameters can be found in the appropriate sections throughout this guide.
For more information regarding SCE platform topology, and for a step-by-step description of the setup
utility, see the
Cisco SCE 2000/SCE 1000 Installation and Configuration Guides.
SNMP agent status
SNMP agent status Enable or disable SNMP management.
GET community names
Community strings to allow GET access and associated ACLs
(maximum 20).
SET community names
Community strings to allow SET access and associated ACLs
(maximum 20).
trap managers (maximum 20)
Trap manager IP address, community string, and SNMP version.
Authentication Failure trap
status
Sets the status of the Authentication Failure traps.
enterprise traps status
Sets the status of the enterprise traps.
system administrator
Name of the system administrator.
Topology Configuration (All Platforms)
connection mode
Is the SCE platform installed in bump-in-the-wire topology (inline)
or out of line using an optical splitter or external switch
(receive-only)?
Admin status of the SCE
platform after abnormal boot
After a reboot due to a failure, should the SCE platform remain in a
Failure status or move to operational status provided no other
problem was detected?
Topology Configuration (SCE 1000)
link bypass mode on operational
status
When the SCE 1000 is operational, should it bypass traffic or not?
redundant SCE 1000 platform?
Is there a redundant SCE 1000 installed as a backup?
link bypass mode on
non-operational status
When the SCE 1000 is not operational, should it bypass traffic or
cut it off?
Topology Configuration (SCE 2000)
type of deployment
Is this a cascade topology, with two SCE platforms connected via
the cascade ports? Or is this a single platform topology?
physically connected link
(cascade topology only)
In a cascade deployment this parameter sets the index for the link
that this SCE 2000 is deployed on. The options for the SCE 2000
are link-0 or link-1.
In a single-SCE 2000 Platform deployment this parameter is not
relevant since one SCE 2000 is deployed on both links. In this case
the link connected to port1-port2 is by default link-0 and the link
connected to port3-port4 is by default link-1.
priority (cascade topology only)
If this is a cascaded topology, is this SCE 2000 the primary or
secondary SCE 2000?
on-failure behavior (inline
connection mode only)
If this SCE 2000 is deployed inline, should the failure behavior be
bypass or cutoff of the link?
Table 4-1
Setup Command Parameters (continued)
Parameter
Definition