![Cisco Catalyst 9400 Series Hardware Installation Manual Download Page 97](http://html.mh-extra.com/html/cisco/catalyst-9400-series/catalyst-9400-series_hardware-installation-manual_64376097.webp)
Fan tray without the adapter being installed
from the front
2
Front side of the fan tray
1
Step 3
Slide the fan tray into the chassis until the two captive installation screws make contact with the chassis.
Step 4
Tighten the two captive installation screws on the front, to secure the fan tray assembly in the chassis.
Step 5
Verify that you have installed the fan tray correctly. See
Verifying Fan Tray Installation, on page 95
.
Removing a Fan Tray from the Rear
When you remove a fan tray from the rear, the fan tray assembly is removed. This includes the fan tray and
the adapter. To remove a fan tray from the rear, follow the steps described here.
When removing the fan tray, keep your hands and fingers away from the spinning fan blades. Let the fan
blades completely stop before you remove the fan tray.
Statement 258
Warning
Only trained and qualified personnel should be allowed to install, replace, or service this equipment.
Statement
1030
Warning
Cisco Catalyst 9400 Series Switches Hardware Installation Guide
91
Removing and Replacing FRUs
Removing a Fan Tray from the Rear