16-22
Cisco Security Appliance Command Line Configuration Guide
OL-12172-03
Chapter 16 Identifying Traffic with Access Lists
Logging Access List Activity
To configure the maximum number of deny flows and to set the interval between deny flow alert
messages (106101), enter the following commands:
•
To set the maximum number of deny flows permitted per context before the security appliance stops
logging, enter the following command:
hostname(config)#
access-list deny-flow-max
number
The
number
is between 1 and 4096. 4096 is the default.
•
To set the amount of time between system messages (number 106101) that identify that the
maximum number of deny flows was reached, enter the following command:
hostname(config)#
access-list alert-interval
secs
The
seconds
are between 1 and 3600. 300 is the default.