WALLBOX SMART
– INSTRUCTION MANUAL
6.2.4 OCPP SETTINGS
Select properly values according to OCPP central system parameters. Please contact
to your administrator to select the correct values.
Value
Description
Use local white-list
Yes:
store a list of authorised users on
the charge point.
No:
Authorization is consulted for each
RFID card shown.
Use OCPP time synchronization
Time synchronization between charge
point and OCPP central system.
Compress OCPP messages
Sending compressed messages between
charge point and central system.
NOTE:
Before enabling this option
consult to your OCPP administrator if
central system allows this function.
Energy for Start/Stop transaction
Partial:
Send partial energy consumption
while vehicle is charging.
Total:
Send total energy values of
energy meter.