Maintenance
MediaVault U320-R, U320-RX User Manual
8-8
MV U320-R, MV U320-RX_Ciprico Inc.
For Disk Drive Modules (RAID 3 only)
This procedure assumes that the array was previously formatted in RAID 3
mode and that it is running at least ENG17B firmware.
A failed disk in RAID 3 mode is indicated by three sets of beeps (each set
of beeps will be the number of the disk drive module) when the
MV U320-R or MV U320-RX is powered-up. The sets of beeps are
followed by a continuous tone.
In addition, the LED located next to the failed disk drive module will flash,
and the service LED for that channel will be illuminated.
1.
Power-up the MV U320-R, MV U320-RX only. (The series of 3 sets of
beeps are heard).
2.
When a continuous tone is heard, quickly press the
M
ODE
S
ET
button at
the back of the MV U320-R, MV U320-RX once. The continuous tone is
silenced.
3.
Remove the replacement disk drive module from its protective anti-
static bag. (Save the bag, for returning the defective disk drive module).
4.
Gently insert the replacement disk drive module in the bay.
5.
Push down the handle while gently inserting the disk drive module, until
a “click” is heard.
6.
Install the front panel onto the MV U320-R, MV U320-RX.
7.
Press and hold the
M
ODE
S
ET
button until two beeps are heard.
Release the button.
8.
All of the drive LEDs for that channel will illuminate. This indicates that
the rebuild (reconstruction) process has begun.