MV U320-R, MV U320-RX_Ciprico Inc.
8-7
MediaVault U320-R, U320-RX User Manual Maintenance
Install and Rebuild a Disk Drive Module
For Disk Drive Modules in RAID 0 Mode
A failed disk drive module in RAID 0 mode is indicated by a series of
beeps. The beep indicate the number of the drive that failed. As the beeps
occur, the LED nearest the defective disk drive module is illuminated.
1.
Gently insert the new disk drive module into the bay.
2.
Push down on the handle while pushing the disk drive module inwards,
until a “click” is heard.
3.
Reinstall the front panel of the MV U320-R, MV U320-RX.
4.
Apply power to the MV U320-R, MV U320-RX (the beeps should no
longer be heard).
5.
Apply power to the host computer.
Format/partition/stripe the array using the procedures described in
Chapter 6,
Configuration
. Restore data to the array if a backup is
available.
CAUTION: The previous volume might appear on
the monitor. Do not attempt to use this volume!
The data on this volume is corrupt
.