Using Remote Control
5-37
Setting syntax: none
Setting parameters: none
Query syntax:
PROTection?<PMT>
Return parameters: <NR1> 0 ~ 65535
Header on:
:IPROTECTION<space><NR1>,<NR1>,<NR1>,<NR1><RMT>
Header off:
<NR1>,<NR1>,<NR1>,<NR1><RMT>
Example:
none
WAVeform:CAPture?
Type: All
channels.
Description:
This query performs the acquisition of new waveform once and
returns the status of this action.
Setting syntax: none
Setting parameters: none
Query syntax:
WAVeform:CAPture?<PMT>
Return parameters: <CRD>, OK | WAIT | ERROR
Header on:
:WAVEFORM:CAPTURE<space><CRD><RMT>
Header off:
<CRD><RMT>
Example:
none
WAVeform:DATA?
<CRD>
Type: Channel-Specific.
Description:
This query returns voltage or current waveform data from the Power
Meter in binary format. The waveform either voltage or current are
consist of 2048 points in format of 32bits float point.
Setting syntax: none
Setting parameters: none
Query syntax:
WAVeform:DATA?<space><CRD><PMT>
Query parameters: <CRD>, V | I
Return parameters: <DLABRD>, #48192<byte1><byte2><byte3>…<byte8192>
Header on:
:WAVEFORM:DATA<space><DLABRD><RMT>
Header off:
<DLABRD><RMT>
Example:
none
SHOW Sub-system
SHOW[:DISPlay]:CHANnel
Type: System.
Description:
This command is used to select which channel will be displayed.
Setting syntax: SHOW:CHANnel<space><arg1>,<arg2>,<arg3>,<arg4><PMT>
Setting parameters: <arg1 ~ 4> denote four display areas, and there are in <NR1> type,
1 ~ 4: Channel 1 ~ Channel 4
#48192<byte1><byte2><byte3><byte4><byte5><byte6><byte7><byte8>...
Point #1
Point #2
Low byte
───→
High byte
Summary of Contents for 66203
Page 1: ...Digital Power Meter 66203 66204 User s Manual...
Page 2: ......
Page 3: ...Digital Power Meter 66203 66204 User s Manual Version 1 0 March 2014...
Page 8: ...vi...
Page 12: ......
Page 22: ......
Page 26: ......
Page 76: ......
Page 126: ......
Page 130: ......
Page 132: ......
Page 136: ......
Page 144: ......