Appendix E Specification Verification
E-7
66203/66204 Range
Voltage: 300V Range Current: 0.02A Range
Fluke 5500 Output
Parameter
Max. Spec.
Measured
Result
Min. Spec.
230Vrms
20mArms
60Hz
PF = 1
W 4.6106
4.5894
PF
1
0.9981
66203/66204 Range
Voltage: 150V Range Current: 0.005A Range
Fluke 5500 Output
Parameter
Max. Spec.
Measured
Result
Min. Spec.
115Vrms
5mArms
60Hz
PF = 1
W 576.32m
573.68m
PF
1
0.9981
66203/66204 Range
Voltage 300V Range Current: 0.02A Range
Fluke 5500 Output
Parameter
Max. Spec.
Measured
Result
Min. Spec.
230Vrms
20Arms
60Hz
PF = 0.8
W 3.6938
3.6662
PF 0.8021
0.7979
66203/66204 Range
Voltage: 150V Range Current:0.005A Range
Fluke 5500 Output
Parameter
Max. Spec.
Measured
Result
Min. Spec.
115Vrms
5mArms
60Hz
PF = 0.5
W 289.05m
285.95m
PF 0.5028
0.4972