Digital Power Meter 66203/66204 User’s Manual
5-32
Setting syntax: INTEGrate<space><CRD><PMT>
Setting parameters: <CRD>, OFF | ON
Query syntax:
INTEGrate?<PMT>
Return parameters: <CRD>, OFF | ON
Header on:
:INTEGRATE<space><CRD><RMT>
Header off:
<CRD><RMT>
Example:
none
[CONFigure:]INTEGrate:TIME
Type: All
channels.
Description:
This command sets the time of integration in Second.
Setting syntax: INTEGrate:TIME<space><NR1><PMT>
Setting parameters: <NR1>, 0 ~ 35999999
Query syntax:
INTEGrate:TIME?[<space><MAX | MIN>]<PMT>
Return parameters: <NR1>, 0 ~ 35999999
Header on:
:INTEGRATE:TIME<space><NR1><RMT>
Header off:
<NR1><RMT>
Example:
none
[CONFigure:]FILTer
Type: All
channels.
Description:
This command is used to switch the low pass filter.
Setting syntax: FILTer<space><CRD><PMT>
Setting parameters: <CRD>, ON | OFF
Query syntax:
FILTer?<PMT>
Return parameters: <CRD>, ON | OFF
Header on:
:FILTER<space><CRD><RMT>
Header off:
<CRD><RMT>
Example:
none
[CONFigure:]THD:MODE
Type: All
channels.
Description:
This command sets the mode of THD measure.
Setting syntax: THD:MODE<space><CRD><PMT>
Setting parameters: <CRD>, FULL | ORDER
Query syntax:
THD:MODE?<PMT>
Return parameters: <CRD>, FULL | ORDER
Header on:
:THD:MODE<space><CRD><RMT>
Header off:
<CRD><RMT>
Example:
none
[CONFigure:]THD:ORDer
Type: All
channels.
Description:
This command sets the order of THD measure.
Setting syntax: THD:ORDer<space><NR1><PMT>
Setting parameters: <NR1>, 2 ~ 100
Query syntax:
THD:ORDer?[<space><MAX | MIN>]<PMT>
Return parameters: <NR1>, 2 ~ 100
Header on:
:THD:ORDER<space><NR1><RMT>
Header off:
<NR1><RMT>
Summary of Contents for 66203
Page 1: ...Digital Power Meter 66203 66204 User s Manual...
Page 2: ......
Page 3: ...Digital Power Meter 66203 66204 User s Manual Version 1 0 March 2014...
Page 8: ...vi...
Page 12: ......
Page 22: ......
Page 26: ......
Page 76: ......
Page 126: ......
Page 130: ......
Page 132: ......
Page 136: ......
Page 144: ......