Digital Power Meter 66203/66204 User’s Manual
5-40
Header off:
<NR2>,<NR2><RMT>
Separator 0: <NR2>,<NR2><RMT>
Separator 1: <NR2>;<NR2><RMT>
Example:
none
[CALCulate:]COMParator:LIMit:VPK+
Type: Channel-Specific.
Description:
This command sets upper and lower boundaries of positive peak
voltage in GONG mode.
Setting syntax: COMParator:LIMit:VPK+<space><NR2>,<NR2><PMT>
Setting parameters: <NR2>, -1 ~ 99999.9999, -1 denote don’t care.
Query syntax:
COMParator:LIMit:VPK+?[<space><MAX | MIN>]<PMT>
Return parameters: <NR2> , -1 ~ 99999.9999
Header on:
:COMPARATOR:LIMIT:VPK+<space><NR2>,<NR2><RMT>
Header off:
<NR2>,<NR2><RMT>
Separator 0: <NR2>,<NR2><RMT>
Separator 1: <NR2>;<NR2><RMT>
Example:
none
[CALCulate:]COMParator:LIMit:VPK-
Type: Channel-Specific.
Description:
This command sets upper and lower boundaries of negative peak
voltage in GONG mode.
Setting syntax: COMParator:LIMit:VPK-<space><NR2>,<NR2><PMT>
Setting parameters: <NR2>, -1 ~ 99999.9999, -1 denote don’t care.
Query syntax:
COMParator:LIMit:VPK-?[<space><MAX | MIN>]<PMT>
Return parameters: <NR2> , -1 ~ 99999.9999
Header on:
:COMPARATOR:LIMIT:VPK-<space><NR2>,<NR2><RMT>
Header off:
<NR2>,<NR2><RMT>
Separator 0: <NR2>,<NR2><RMT>
Separator 1: <NR2>;<NR2><RMT>
Example:
none
[CALCulate:]COMParator:LIMit:THDV
Type: Channel-Specific.
Description:
This command sets upper and lower boundaries of total harmonic
distortion of voltage in GONG mode.
Setting syntax: COMParator:LIMit:THDV<space><NR2>,<NR2><PMT>
Setting parameters: <NR2>, -1 ~ 99.99, -1 denote don’t care.
Query syntax:
COMParator:LIMit:THDV?[<space><MAX | MIN>]<PMT>
Return parameters: <NR2> , -1 ~ 99.99
Header on:
:COMPARATOR:LIMIT:THDV<space><NR2>,<NR2><RMT>
Header off:
<NR2>,<NR2><RMT>
Separator 0: <NR2>,<NR2><RMT>
Separator 1: <NR2>;<NR2><RMT>
Example:
none
[CALCulate:]COMParator:LIMit:I
Type: Channel-Specific.
Description:
This command sets upper and lower boundaries of current (r.m.s.)
Summary of Contents for 66203
Page 1: ...Digital Power Meter 66203 66204 User s Manual...
Page 2: ......
Page 3: ...Digital Power Meter 66203 66204 User s Manual Version 1 0 March 2014...
Page 8: ...vi...
Page 12: ......
Page 22: ......
Page 26: ......
Page 76: ......
Page 126: ......
Page 130: ......
Page 132: ......
Page 136: ......
Page 144: ......