Programmable Bidirectional DC Power Supply 62000D Series
Operating and Programming Manual
5-20
Description:
Sets the output power (watt).
Syntax:
SOURce:POWer <NRf+>[suffix]
Parameter:
Refer to individual spec for valid numeric range.
Example:
SOUR:POW 1
It sets the output power to 1 watt.
SOUR:POW 60.00
It sets the output power to 60 watt.
Query Syntax:
SOUR:POW? [{MAX/MIN}]
Return Parameter:
<NRf+> [Unit=Watt]
Query Example:
SOUR:POW?
It returns the power.
SOUR:POW? MAX
It returns the max. power can be set.
Return Example:
1.00
10. SOURce:POWer:LIMit:{HIGH/LOW}
Description:
Sets the output power range.
Syntax:
SOURce:POWer:LIMIT:HIGH
<NRf+>[suffix]
SOURce:POWer:LIMIT:LOW
<NRf+>[suffix]
Parameter:
Refer to individual spec for valid numeric range.
Example:
SOUR:
POW
:LIMIT:HIGH 60.0 It sets the output power range
to 600V maximum
SOUR:
POW
:LIMIT:LOW 20.0 It sets the output power range to
200V minimum.
Query Syntax:
SOUR:POW:LIMIT:HIGH?
[{MAX/MIN}]
SOUR:POW:LIMIT:LOW?
[{MAX/MIN}]
Return Parameter:
<NRf+> [Unit=Watt]
Query Example:
SOUR:
POW
:LIMIT:HIGH?
It returns the power high limit.
SOUR:
POW
:LIMIT:HIGH? MAX It returns the max. power can
be set.
Return Example:
8.01
Note
Source and Load functions share this setting.
11. SOURce:POWer:PROTect:HIGH
Description:
Sets the power range for over power protection.
Syntax:
SOURce:POWer:PROTect:HIGH <NRf+>[suffix]
Parameter:
Refer to individual spec for valid numeric range.
Example:
SOUR:POW:PROT:HIGH 1260 It sets the high limit to
1260W for power output
protection.
Query Syntax:
SOUR:POW:PROT:HIGH? [{MAX/MIN}]
Return Parameter:
<NRf+> [Unit=Watt]
Query Example:
SOUR:POW:PROT:HIGH? It returns the high limit of
power protection.
SOUR:POW:PROT:HIGH? MAX It returns the max. power
protect can be set.
Return Example:
1.03
12. SOURce:DCON:{RISE/FALL}
Description:
Sets the DC_ON signal active point.
Syntax:
SOURce:DCON:RISE <NRf+>[suffix]
SOURce:DCON:FALL <NRf+>[suffix]
Parameter:
Refer to individual spec for valid numeric range.
Example:
SOUR:DCON:RISE 79.5
It sets the DC_ON rise to
79.5V.
SOUR:DCON:FALL 0.5 It sets the DC_ON fall to 0.5V.
Query Syntax:
SOUR:DCON:RISE? [{MAX/MIN}]
Summary of Contents for 62000D Series
Page 1: ......
Page 2: ...Get more information by downloading Chroma ATE Solutions APP ...
Page 8: ...vi ...
Page 9: ...vii ...
Page 10: ...viii ...
Page 14: ......
Page 18: ......
Page 35: ...Overview 1 17 Figure 1 6 Dimension of 62000D 600 1200 1800 Models ...
Page 36: ......
Page 52: ......
Page 63: ...Manual Operation 3 11 Figure 3 13 Figure 3 14 ...
Page 109: ...Manual Operation 3 57 _EXT ON SIGNAL EXT ON DISABLE EXT ON ENABLE Output Output Figure 3 85 ...
Page 110: ......