Programmable Bidirectional DC Power Supply 62000D Series
Operating and Programming Manual
5-16
15. CONFigure:MSTSLV:READY?
Description:
Queries the Master/Slave connection status.
Syntax:
CONFigure:MSTSLV:READY?
Return Parameter:
ON | OFF | WAIT
Query Example:
CONFigure:MSTSLV:READY?
Return Example:
ON | OFF | WAIT
16. CONFigure:MSTSLV
Description:
Executes the Master/Slave control.
Syntax:
CONFigure:MSTSLV <Arg>
Parameter:
<Arg>: ON | OFF
Example:
CONFigure:MSTSLV ON
Query Syntax:
CONF:MSTSLV?
Return Parameter:
ON | OFF
Query Example:
CONF:MSTSLV?
Return Example:
ON
Note
1.
Set the following 3 command before controlling this function:
CONFigure:MSTSLV:ID
ONFigure:MSTSLV:PARSER
CONFigure:MSTSLV:NUMSLV
Use CONFigure:MSTSLV:READY? to query the connection status at present. If the
status is WAIT, query again until the status is ON | OFF to perform this function.
2.
When Program RUN is executed, series/parallel control is not available.
17. CONFigure:INHibit
Description:
Executes the Remote Inhibit control.
Syntax:
CONFigure:INHibit <Arg>
Parameter:
<Arg>: DISABLE | ENABLE
Example:
CONFigure:INHibit DISABLE
Query Syntax:
CONFigure:INHibit?
Return Parameter:
DISABLE | ENABLE
Query Example:
CONFigure:INHibit?
Return Example:
DISABLE
18. CONFigure:INHibit:PULL
Description:
Executes the Remote Inhibit input signal to enhance the
resistance control.
Syntax:
CONFigure:INHibit:PULL <Arg>
Parameter:
<Arg>: LOW | HIGH
Example:
CONFigure:INHibit:PULL LOW
Query Syntax:
CONFigure:INHibit:PULL?
Return Parameter:
LOW | HIGH
Query Example:
CONFigure:INHibit:PULL?
Return Example:
LOW
19. CONFigure:INTERLOCK
Description:
Executes the Safety Interlock control.
Syntax:
CONFigure:INTERLOCK <Arg>
Parameter:
<Arg>: DISABLE | ENABLE
Example:
CONFigure:INTERLOCK DISABLE
Query Syntax:
CONFigure:INTERLOCK?
Return Parameter:
DISABLE | ENABLE
Summary of Contents for 62000D Series
Page 1: ......
Page 2: ...Get more information by downloading Chroma ATE Solutions APP ...
Page 8: ...vi ...
Page 9: ...vii ...
Page 10: ...viii ...
Page 14: ......
Page 18: ......
Page 35: ...Overview 1 17 Figure 1 6 Dimension of 62000D 600 1200 1800 Models ...
Page 36: ......
Page 52: ......
Page 63: ...Manual Operation 3 11 Figure 3 13 Figure 3 14 ...
Page 109: ...Manual Operation 3 57 _EXT ON SIGNAL EXT ON DISABLE EXT ON ENABLE Output Output Figure 3 85 ...
Page 110: ......