Overview
1-5
System Fault indicator
(O/P)
TTL: Active Low
Safety interlock (I/P)
Time accuracy: <100ms
Remote inhibit (I/P)
TTL: Active Low
Series & Parallel
operation
Master / Slave control for 10 units.
(Series: 2 units / Parallel: 10 units)
Auto Sequencing (List
mode)
Number of program
10
Number of sequence
100
Dwell time Range
2ms
– 15,000s
Trig. Source
Manual / Auto / External
Auto Sequencing (Step
mode)
Start voltage
0 to Full scale
End voltage
0 to Full scale
Run time
hh : mm : ss.sss ( 00 : 00 : 00.001 to 99 : 59 : 59.999 )
Trig. Source
Auto
Input Specification
AC input voltage
3phase, 3wire + ground
3Φ 200Vac - 220Vac ±
10%
3Φ 380Vac - 480Vac ±
10%
(Output=4kW@200-
220 Vac input,
Output=6kW@380-
480 Vac input)
w/o Neutral
3Φ 200Vac - 220Vac
± 10%
3Φ 380Vac - 480Vac
± 10%
(Output=8kW@200-
220 Vac input,
Output=12kW@380-
480 Vac input)
w/o Neutral
3Φ 200Vac - 220Vac ±
10%
3Φ 380Vac - 480Vac ±
10%
(Output=12kW@200-
220 Vac input,
Output=18kW@380-
480 Vac input)
w/o Neutral
AC frequency range
47
– 63 Hz
Power factor
Source
PF>0.97 @220Vac
PF>0.97 @380Vac
PF>0.95 @480Vac
Regn
PF>0.97 @220Vac
PF>0.95 @380Vac
PF>0.92 @480Vac
Source
PF>0.97 @220Vac
PF>0.97 @380Vac
PF>0.95 @480Vac
Regn
PF>0.97 @220Vac
PF>0.95 @380Vac
PF>0.92 @480Vac
Source
PF>0.97 @220Vac
PF>0.97 @380Vac
PF>0.95 @480Vac
Regn
PF>0.97 @220Vac
PF>0.95 @380Vac
PF>0.92 @480Vac
General Specification
Maximum Remote
Sense Line Drop
Compensation
12
2% of full scale voltage per line(4% total)
Operating Temperature
Rage
0
C ~ +40
C
Storage Temperature
Rage
-25
C ~ +70
C
Dimension Size
(HxWxD)mm
133 x 428 x 730 mm / 5.23 x 16.85 x 28.74 inch
Weight (kg)
27kg / 60lbs
36kg / 80lbs
45kg / 100lbs
Summary of Contents for 62000D Series
Page 1: ......
Page 2: ...Get more information by downloading Chroma ATE Solutions APP ...
Page 8: ...vi ...
Page 9: ...vii ...
Page 10: ...viii ...
Page 14: ......
Page 18: ......
Page 35: ...Overview 1 17 Figure 1 6 Dimension of 62000D 600 1200 1800 Models ...
Page 36: ......
Page 52: ......
Page 63: ...Manual Operation 3 11 Figure 3 13 Figure 3 14 ...
Page 109: ...Manual Operation 3 57 _EXT ON SIGNAL EXT ON DISABLE EXT ON ENABLE Output Output Figure 3 85 ...
Page 110: ......