15
For help with connections or any other information, use the on-line help.
In the case of a resistance measurement (k
W
), there is no current reversal and no compensation for the measurement leads.
3.2.4. ERRoR InDICAtIon
The commonest error in the case of a continuity measurement is the presence of a voltage on the terminals. An error message is
displayed if a voltage greater than 0.5 VRMS is detected and you press the TEST button.
In this case, the continuity measurement is not enabled. Eliminate the cause of the interference voltage and start the measure-
ment over.
Another possible error is measurement of an overly inductive load that prevents the measurement current from stabilizing. In this
case, start the measurement in permanent mode with only one polarity and wait for the measurement to stabilize.
1 . 5
8 k
Ω
1 %
..\..
2
.
00 k
Ω
- - .- Hz
RESISTANCE
02
/
10
/
2009 10
:
47
Value of the alarm threshold.
Measurement result.
Case where the measurement is
below the alarm threshold.
Use the key to see the rest of the
measurement display.
Permanent mode.