28
Figure
12.4.
Down-camera image of the calibration board.
(2)
Calibrate nozzle 1\2:
This alignment must be done after the step
“calibrate
cameras
”. In the popup window, move the nozzle to the center of the crosshairs
and click “Set”;
(3)
Calibrate pull needle, single
…:
This alignment was described previously in the
“Align Feeders” section.
(4)
Calibrate pull needle 1, entire:
Align feeder 1, then applied to all feeders using
known locations separations. Use for initial (coarse) feeder settings;
(5)
Calibrate PCB points:
Chooses 2- or 3-point calibration for PCB.
(6)
Pick offsets used:
Button toggles on and off to enable offsets to the feeders for
the pick operation, as defined as the feeder offset in
the “Run / Edit” section.
When selected, red text is shown in
“Feeder Edit” window;
(7)
Vacuum detection set:
View and set parameters of the vacuum setpoints; see
section below for details;
(8)
Backup/
Restore:
Backup and restore all of parameters in system set;
(9)
Save:
Click to save changes of system set. If system parameters were modified
without saving, then old parameters will be used after next restart;
(10)
Software identification:
The lower left corner displays the software version;